Desa CD32M(-1)(-2) Indoor Fireplace User Manual


 
- 10 - For more information, visit www.desatech.com
Place log #6 (left log) onto left pin of front log (#2)
and the smooth surface of rear log (#3). Make sure it
is seated properly.
Place log #7 onto right pin of top log (#5). Make sure
it is seated properly.
NOTICE: Do not put lava rock on or under the burner.
Placing lava rock on burner could cause performance
problems.
Pull ember material apart into pieces no larger than a
dime. Place these pieces loosely and directly onto
the exposed section of the front burner and along the
space between the burner and grate prongs. These
will create the glowing ember appearance as the
flame touches the ember material. Do not block air
slots by using too much ember material in one area.
It is not necessary to use all of the ember material
provided.
Close glass door, lock door latches and secure
louvers in place.
BURNER FLAME ADJUSTMENT
The burner flame adjustment (shutter opening) is factory
preset (for natural gas) to the proper air-to-gas ratio. This ratio
results in an even and clean burning flame across the burner
(see figure 19).
If adjustment is necessary, you can restore the proper flame
setting by loosening the air shutter screw and rotating the air
shutter until proper setting is achieved (see figure 20). The
correct shutter opening is listed below.
DECORATIVE FACING
Any non-combustible material may be used as facing (glass,
tile, brick etc.) as long as the proper clearances are observed
(refer to section on clearances on page 3). Louvered openings
must not be obstructed and upper and lower panels must
remain accessible for service. Use only heat-resistant, non-
combustible mortar or adhesive when securing decorative
facing materials.
OPERATING GUIDELINES
When lit for the first time, the fireplace may emit a slight odor
for about 16 to 24 hours. This is normal and is due to the
“curing” of the logs and the “burn-in” of internal paint and
lubricant used in the manufacturing process.
Keep compartments, logs, burners and area surrounding the
logs clean by vacuuming and brushing at least twice a year or
as necessary.
Turn off gas and remote wall switch before servicing
appliance. Any safety screen or guard removed for servicing
the fireplace must be replaced prior to operation. Have a
qualified agency periodically inspect the vent system at the
start of each heating season for any obstruction, which hinder
its normal operation. Never obstruct the flow of combustion
and ventilation air. Keep the front of the fireplace clear of all
obstacles and materials.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury o
r
p
roperty damage. Refer to this manual for assistance.
Consult a qualified installer for additional information.
Figure 19 BURNER FLAME
WIRING DIAGRAM
NATURAL PROPANE NATURAL PROPANE
CD32M 0.188" MAX - -
CD36M 0.188" MAX - -
CD42M 0.188" 0.313" 0.188" 0.500"
TUBE BURNER PAN BURNER
AIR SHUTTER OPENINGS
MODEL
Figure 20 AIR SHUTTER ADJUSTMENTS
WARNING: The glass door must be securely in place
before operating the fireplace. Do not operate the fireplace
if glass is missing or broken.