In selecting a location, the following precautions must be
observed:
Do not connect this appliance to a chimney system
used for solid fuel burning fireplace.
Due to high temperatures, do not locate this appliance
in high traffic areas or near furniture and draperies.
Never obstruct the front opening of the appliance or
the flow of combustion and ventilation air. Keep
control compartments accessible.
Do not locate close to where gasoline or other
flammable liquids may be stored. The appliance area
must be kept clear and free from these combustible
materials.
Do not use this appliance if any part has been under
water. Immediately contact a local service technician
to examine the fireplace and to replace any part of the
control ignition system and other related components
that has been submerged under water.
MINIMUM CLEARANCES TO COMBUSTIBLES
Back and side of fireplace ------------------- 0”
Floor ------------------------------------------ 0”
Perpendicular wall --------------------------- 6”
Front ------------------------------------------- 36”
Top of Standoffs ----------------------------- 0”
MANTEL CLEARANCES
Woodwork, such as wood trims, mantels and other
combustible materials should be placed within the required
clearance specified on figure 2.
VENT TERMINATION CLEARANCES
The final position of your fireplace depends on the location of
the vent termination in relation to the clearances that must be
observed as shown in figures 3 and 4.
Fi
g
ure 2 MANTEL CLEARANCES
Ref. Mantel Depth Ref. Mantel from top
of opening
114"A16"
212"B14"
310"C12"
48"D10"
56"E8"
64"F6"
72"G4"
WARNING: Do not block required air space wit
h
insulation or any other material. Do not obstruc
t
effective opening of appliance with any type of facing
material.
Figure 4 VENT CLEARANCES
Figure 3 VENT CLEARANCES