CGHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off.
When turning burners off, the pilot will remain lit.
CGHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on the hand-held remote
control (see Figure 58). The lights to the left of the button
will show AUTO, ON, or OFF.
In the ON mode, the burners will ignite. The heater is in
manual mode when ON is lit.
In the AUTO mode, the thermostat in the hand-held re-
mote unit controls the room temperature. To increase the
room temperature, press the top arrow of the TEMP but-
ton. To lower the room temperature, press the bottom
arrow of the TEMP button. At higher settings the heater
will run longer.
IMPORTANT:
This remote control has been specially
engineered to take an air temperature sample every 5.5
minutes in the auto mode. It will not respond immedi-
ately to the temperature setting being turned up or down.
IMPORTANT:
The hand-held remote control unit must
be near the heater. Do not keep the hand-held remote
control unit too close to the heater. The thermostat on
the hand-held remote control unit will heat up too quickly
and turn the fireplace off.
3. To turn the burner off, press the AUTO/ON/OFF button
until OFF lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off, manually turn the con-
trol knob on the heater to the OFF position.
OPERATING STOVE WITH BURNER SYSTEM
Optional Remote Operation (Cont.)
Operating Optional Blower Accessory
OPERATING STOVE WITH
BURNER SYSTEM
Continued
Figure 57 - Setting the Selector Switch, Gas Control Knob, and
Variable Control Knob for Remote Operation
ON
OFF
REMOTE
L
O
H
I
OFF
ON
P
I
L
O
T
Selector Switch in Remote
Position (Optional Remote
Control)
Variable Control Knob
Gas Control Knob
in On Position
Figure 58 - Hand-Held Thermostat Remote Control Unit
Selections (CGHRCTA Only)
Shows
Temperature
Setting
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On
or Off and Allows
You to Choose the
Auto Setting
The Log Heater
will Automatically
Cycle between
Pilot and the Heat
Setting that has
been Selected
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate the blower controls by opening the lower door on the
stove. Blower controls are located on the left side of the switch
bracket to the left just inside the door.
Both the GA3700 manual blower and the DA3610T thermo-
statically-controlled blower have an ON setting and an OFF
setting. The blower will only run when the switch is in the ON
position. In the OFF position, the blower will not operate.
Note for DA3610T Only:
If you are using DA3610T blower
with optional thermostat (wall mount or remote control) for the
burner system, your burner system and blower will not turn on
and off at the same time. The burner system may run for several
minutes before the blower turns on. After the burner system
modulates to the pilot position, the blower will continue to run.
The blower will shut off after the burner system temperature
decreases.
The blower helps distribute heated air from the burner system.
Periodically check the air passageways of the burner system
and remove any dust, dirt, or other obstructions that will hinder
the flow of air.