Dansons Group IGB Stove User Manual


 
5
DO NOT operate the stove if the flame becomes dark and sooty or if the firepot overfills with pellets. Push
the OFF Touch Pad and inspect the heater. (See Operating Your Stove). Soot or creosote may accumu-
late in the exhaust vent system when the stove is operated under incorrect conditions such as an ex-
tremely rich burn. The flame will have a lazy orange color with black tips. This indicates poor pellet fuel
combustion.
NEVER block free airflow through the open vents of the unit. The viewing door and ash pan must be
closed and latched during operation.
The pellet appliance exhaust system works with negative combustion chamber pressure and a positive
chimney pressure, therefore the exhaust system must be completely airtight and properly installed. All
exhaust system vent joints must be sealed, gas tight, with HI-TEMP RTV silicone sealant, and/or at least
3 sheet metal screws per joint and to the heater also.
Your heater requires periodic maintenance and cleaning (Refer to ”Routine Cleaning” section of the
manual). Failure to maintain your heater may lead to smoke spillage in your home.
Disconnect the power cord from the electrical outlet before performing any maintenance. Pushing ”OFF”
Touch Pad does not disconnect all power to the heater.
BEFORE carrying out any maintenance or cleaning, allow the heater to cool. Ashes must be disposed in a
metal container with a tight lid and placed on a non-combustible surface or on the ground, well away from
all combustible materials, pending final disposal.
The exhaust system should be checked twice a year minimum for any build-up of soot or
creosote. Do not touch the hot surfaces of the heater.
S
S
AFETY
AFETY
T
T
ESTING
ESTING
NOTE: Canadian Comfort Industries grants no warranty, implied or stated, for the installation or
maintenance of your appliance, and assumes no responsibility of any consequential damage(s).
In accordance with the procedures and specifications listed in UL1482 – 1998 & ASTM E 1509-04, and
ULC-S627-00 and ULC-S628-M93 for solid fuel room heater. Tested and listed for use in Manufactured
Homes in accordance with Oregon Administrative Rules 814-23-900 through 814-23-909. The Canadian
Comfort Industries pellet stove has been independently tested and listed by INTERTEK (an accredited testing
laboratory) to UL, ULC and CSA standards. It is tested and listed for residential installation according to current
national and local building codes as:
A Freestanding Room Heater
A Fireplace Insert
A Built-in Insert
A Hearth Stove
A Mobile Home Heater.
The Safety Listing Label is located on the rear
inspection panel for model CCGB1 and CCGB2.
Please read the label carefully.
It contains important information
about installation and operation of your
pellet appliance.
Note that your STOVE’S serial number is located
on the safety label. Your appliance serial
Number is preceded by a “WH-“
(example WH-00000).
(see diagram)
Glow Boy Pellet & Biomass www.glowboystoves.com 5