OPERATING IN THERMOSTAT ON / OFF (Flashing 1 & 2)
This also requires purchasing the optional “Wall Thermostat Add-on Kit”
This mode of operation is best suited for those “Take of the Chill” nights of spring,
summer , fall.. The thermostat should be set for the desired room temperature. If the
room temperature drops below the level on the thermostat the stove will automatically
begin the start-up cycle, as explained in the manual operation section.
In this mode the life of the IGNITER is reduced and the power consumption will be
higher. If the thermostat calls for heat while the stove is still cooling down, the stove
will go through the START-UP cycle.
TO START
Once this mode has been selected, you simply press the START touch pad to
Activate the stove. Once the start-up cycle is completed the stove run on the
pre-selected “HIGH” (number 2,3 or4) setting, till the temperature is reached.
TO ADJUST HEAT
You can select the HIGH heat output level (2,3 or 4) by pushing the START touch pad,
you can also select the FAN setting you desire. The stove will now go through its
normal start up cycle. Once completed the appliance is now in the ON / OFF mode.
For optimum heat transfer, the FAN setting should be set at LOW or MEDIUM. The appliance will run the FAN at HIGH
speed when needed, automatically.
TO SHUT DOWN
The thermostat will shut the stove down when the desired room temperature is reached. The Feed Rate num-
bers 1 & 2 will flash while the appliance is in the OFF part of this mode to give you a visual indication that the
appliance is still active and in the ON / OFF cycle.
HINT: If you find that the stove turns off and on repeatedly, you may wish to turn the FEED RATE to a lower
setting. The lower setting will provide a more consistent heat output over time, eliminating the need for the
thermostat to repeatedly turn the stove off.
Feed Rates 1 & 2
U
U
NDERSTANDING
NDERSTANDING
T
T
HE
HE
C
C
ONTROL
ONTROL
HI
MED
LOW
FAN SPEED
OFF
FAN
SPEED
A
UGER
CYCLE
Glow Boy Pellet & Biomass www.glowboystoves.com 28
FINE TUNE ADJUSTMENTS
14
FAN
Increase
Decrease
TRIM POTS (Fine Tune Adjustments)– Factory Settings
FUEL FEED rates at the Lowest (number 1) and highest (number 4) settings can be adjusted by
adjusting the fine tune trim pots located on the control panel. To raise fuel feed turn trim pot
counter clockwise and to lower turn clockwise. To assist in knowing what the change is you
should note the amount of time the light on the AUGER CYCLE LED stays OFF. (Note: The light
stays on when ever the fuel feed motor, AUGER CYCLE, is running). Lengthening the time this
LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed
.
FAN (Combustion) TRIM; this trim may be used to raise or lower the amount of air moving
through the burn grate for the cleanest burn, ONLY when the control is on the Low Feed Rate (1),
and only after the Air Inlet damper has been set during the High Feed Rate (4)..
Note: If you attempt to adjust the Trim Pots, use a small precision screwdriver.
The Trim Pots do not make a full rotation. If using a metal screwdriver, be gentle as the
plastic trim pot slot can be damaged or stripped.
AUGER CYCLE
The AUGER CYCLE LED indicates when a electrical signal is being sent to the auger motor. It is
NOT used to indicate the actual movement of the auger. When the signal is being sent the LED will
be solid for 3 seconds. When the LED is off no signal is being sent
.
FAN SPEED (Convection or heating)
The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat
exchange tubes and back into the room. The FAN SPEED has 5 different speeds, these are con-
trolled by pushing the FAN SPEED touch pad. The Low LED will be solid when on the lowest fan
speed, the LOW & MED will both be solid when the next highest speed is selected and so on.
.When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa
versa.