Cumberland Stove Works OMMF3500 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 26 800-345-6007
CumberlandStoveWorks.com
PROBLEM CAUSE: Loss of vacuum
? Stove fans are not running.
Make sure glass door is shut and
sealed tightly. If not, adjust door handle
or replace gasket.
Leaking outside vent. Check the
venting system for traces of smoke.
Heated room is under negative pres-
sure, check the make-up air fans and
ducts.
TRI-X controller display screen will instruct what
key must be pushed to restart the stove. If fuel type
is changed, remember to push the OFF key until the
screen reads [SELECT FUEL TYPE USE MODE
KEY].
Hopper empty, refill.
Contact service provider if above remedies fail at 800-345-6007.
WARNING! Negative pressure in a home is a serious issue. If there is a problem, the stove should be installed with a Fresh
Air Kit (not included).