Cumberland Stove Works OMMF3500 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 11800-345-6007
CumberlandStoveWorks.com
6”
6”
6”
3”
PARLOR STOVE FLOOR PAD CLEARANCES
INSTALLATION
It is recommended the stove be installed and serviced by
authorized professionals who are certified by the National
Fireplace Institute (NFI) as NFI Pellet Specialists.
Proper installation of this stove is necessary for safe and
efficient operation. Installing this product improperly may
result in a house fire and personal injury. All applicable
building codes for your location must be followed. In
areas where building codes require additional steps to
the installation of this product not included in this manual,
the building codes will take precedent and must be
followed. Contact your local building inspector to obtain
any necessary permits or inspection guidelines before
installing the product.
STOVE PLACEMENT
Sketch out a plan for installing the stove including dimensions
before permanent placement. When determining the
location for the stove, wall stud location is critical. You may
need to adjust the location of the stove to avoid trying to
vent through a wall stud. Before placing the parlor stove,
connect the vent and allow for minimum clearance to
combustible walls.
FLOOR PROTECTION REQUIREMENTS
The stove must be installed on a noncombustible floor, with
proper floor protection, or on a masonry hearth. The hearth
or noncombustible floor protector must extend a minimum
of 6” in front, 6” from each side, and 3” from back. The
minimum floor protector material is 24 gauge sheet metal.
The floor protector must extend 2” beyond each side and
rear of the T-vent.
WARNING
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL
AND USE THIS STOVE. FAILURE TO FOLLOW THE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURES
AND SHOULD STAY AWAY TO AVOID BUMPS TO SKIN
AND/OR CLOTHING.
YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE SAME ROOM
AS THE STOVE.
CLOTHING AND OTHER FLAMMABLE MATERIALS
SHOULD NOT BE PLACED ON OR NEAR THIS UNIT.
CAUTION
THIS STOVE SHOULD NOT BE USED AS THE ONLY
SOURCE OF HEAT IN THE HOUSE. POWER OUTAGES
AND PERIODIC MAINTENANCE WILL RESULT IN A
TOTAL LOSS OF HEAT.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS
MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT,
FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE
NEED FOR A PERMIT.
KEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS,
LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE
OUTLET ON THE OUTSIDE OF THE BUILDING.
INSTALLATION AND REPAIR OF THIS PARLOR STOVE
SHOULD BE DONE BY A QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A QUALIFIED
SERVICE PERSON. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS, AND CIRCULATING AIR
PASSAGEWAYS OF THE STOVE BE KEPT CLEAN.