Cumberland Stove Works OMMF3500 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 16 800-345-6007
CumberlandStoveWorks.com
OPERATING INSTRUCTIONS
UNDERSTANDING THE TRI-X CONTROLLER
The controller is located on the lower right-hand side of
the parlor stove. It uses an advanced microprocessor that
allows the owner to burn multiple fuels with the touch of a
key. The TRI-X screen will display, for the user, a sequence
of stove functions and any faults that may occur during
operation. Each key functions with a small light (LED) that
indicates stove heat transitions and running status.
ON KEY
Pressing the ON key will begin the startup sequence for
the stove. Fuel will feed through the auger feed system
after a brief exhaust check. This check assures the burn
area is sealed and the flue gases are exiting the building.
The draft fan (exhaust) will start as soon as the ON key is
pressed. The fan will automatically adjust speed to match
the heat requirement. The circulating blower will turn on
when the stove heat level has reached 110°F. When this
temperature is reached, the dial to the right of the TRI-X
controller is used to adjust room blower fan speed. The
TRI-X screen shows the stove progress and will come to
rest on [STOVE CONTROLLED BY TEMP KEY {heat level
1 thru 6}] when the stove is heating normally.
The LED light will illuminate when the ON key is pushed
and remains on during normal operation.
OFF KEY
Pressing the OFF key will cause the stove to begin the
shut-down sequence. If the OFF key is pushed during
normal operation, wait 30 seconds before attempting any
re-light of the fire. Once the fire goes out and the stove
cools down, the blowers will stop running. During a fault
condition, follow the instructions on the TRI-X screen and
push the OFF key until the [SELECT FUEL TYPE USE
MODE KEY] screen appears.
The LED will illuminate when the OFF key is pushed and
remains on when the stove is not providing heat.
MODE KEY
The type of fuel is selected by pressing the MODE key. All
the currently approved fuels can be viewed when scrolling
(pressing) the MODE key.
There is no LED with this key.
TEMP UP OR TEMP DOWN KEYS
Pressing the TEMP UP or the TEMP DOWN keys will adjust
the amount of fuel and air being delivered to the fire pot.
There are six levels of heat from which to choose. Each
level has been calibrated to deliver the correct ratio of air
and fuel into the fire pot for the selected fuel type.
720038
L H
Controller Faceplate
Circulating Blower Dial Faceplate