Cumberland Stove Works OMMF3500 Stove User Manual


 
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 8 800-345-6007
CumberlandStoveWorks.com
SPECIFICATIONS
Model Number MF3500
BTU/hour input 45,000 BTU/HR
Heating Capacity 1,200 Sq. Ft. (2)
Electrical Rating (3) 110 Volts, 15 Amp,
60 Hz
Power Consumption Controller = 5.7 Watts
Stove = 430 Watts
(continuous)
Fuel Storage Capacity 62 lbs.
Flue Size 3 in.
Width 22 in.
Height 40 in.
Depth 22 in.
Weight 287 lbs.
(1) Heat output will vary, depending on the brand, type
and quality of fuel and the moisture content. Consult your
dealer for best results.
(2) Based on post 1982 home construction, requiring 35
BTU/Hr. per Sq. Ft.
(3) Install per NFPA 70 and follow all state and local codes,
contact licensed electrical contractor for assistance.
Certified per ASTM Standards by Intertek Testing Labs.
GLASS SPECIFICATIONS
This stove is equipped with 5mm ceramic glass. Replace
glass only with Cumberland Stove Works ceramic glass
(PN 720002).
CAUTION
THIS INSTALLATION MUST CONFORM WITH LOCAL
CODES. IN THE ABSENCE OF LOCAL CODES YOU MUST
COMPLY WITH ASTM E1509, (UM) 84-HUD, ULC/ORD-
C-1482.
CUMBERLAND STOVE WORKS MANUFACTURER OF
THIS APPLIANCE, RESERVES THE RIGHT TO ALTER ITS
PRODUCTS, THEIR SPECIFICATIONS AND/OR PRICE
WITHOUT NOTICE.