Louisville Tin and Stove BBT103 Gas Heater User Manual


 
The State of Massachusetts requires that installation and service of a gas
appliance be performed by a plumber or gas fitter licensed in the
Commonwealth of Massachusetts.
CONTENTS
Introduction ...................................... 2
Specifications and Dimensions ................. 2
Safety Rules ................................... 3
Clearances ..................................... 4, 5
Location ....................................... 5
Installation ..................................... 6- 10
Lighting Instructions........................... 11
Gas Conversion ......................................... 12
Burner Orifice ................................... 13
Wiring Diagram ................................. 14
Removing Main Burner ......................... 13
Proper Burner Flame ........................... 13
Sequence of Operation ......................... 15
Optional Kits ................................... 16 - 20
Trouble Shooting ............................. 21 - 22
Parts Drawing ................................... 23
Parts List ......................................... 24
Warranty ......................................... 26
INTRODUCTION
THIS IS A GAS-FIRED, DRAFT INDUCED, POWER DEPENDENT, DIRECT VENT WALL FURNACE;
THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN
INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND
OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING,
SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE
AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.
SPECIFICATIONS AND DIMENSIONS
YourDirect VentWall Furnace isshipped complete inone carton. This carton contains the furnace, vent
exhaust tube, air inlet tube, template with rough-in dimensions, installation and operating instructions, power
cord (consult electrical codes), ball-valve w/flex connector, and wall thermostat.
MODEL
NO.
BBT53
BBT54
BBT103
BBT104
INPUT
BTU'HR.
5,000 BTU
1.45KW
5,000 BTU
1.45KW
9,000 BTU
2.61 KW
9,000 BTU
2.61 KW
WIDTH DEPTH HEIGHT
48" 5.375" 9.375"
122cln 13.65cln 23.8cln
48" 5.375" 9.375"
122cln 13.65cln 23.8cm
72" 5.375" 9.375"
183cln 13.65cln 23.8cm
72" 5.375" 9.375"
183cln 13.65cln 23.8cln
GAS TYPE
CO_. GAS
3/8" NAT.
3/8" L.P
3/8" NAT.
3/8" L.P
MAX. WALL
Thickness
16"
41 cm
16"
41 cm
16"
41 cm
16"
41 cm
MIN. WALL
Thickness
4 _
10cm
4 ,7
10cm
4"
10cm
4"
10cm
Page 2