Version 2.0b 49
on/off switch at which time the system will revert to the off state. The prime state is utilized only for filling
the auger with fuel and can only be utilized from an “off state.”
The Manual Stir Control
can only be operated during two states: (a) when the system is shutdown, and (b)
when the system is in the startup phase. The purpose of the manual stir control is to allow the operator to
position the stir rod for easy removal in order to enhance routine cleaning or maintenance during the shutdown
phase. In addition the manual stir control can be utilized to facilitate starting a fire by rotating the stir arm to
enhance air flow during the startup phase.
In order to manually turn the stir arm, the up and down (red and blue) heat arrows must be simultaneously
pressed while the control is in only the OFF PHASE or the STARTUP PHASE. As long as the up and down
heat arrows are held in either the off or startup phase, the stir rod will rotate. Upon releasing either of these
arrows, the stir rod rotation will stop turning. WARNING: Keep hands or loose clothing away from the stir
pot.