Conair UGD031 Thermostat User Manual


 
4-16 l Operation
Function
Control Function Descriptions (continued)
Setup Screens
SCREEN 36
SCREEN 37
SCREEN 38
Screen 39
Screen 41
Screen 42
To access the setup screens, press the
Scroll and “+” buttons at the same time
and hold for ten seconds from the Process
screens. To get out of the setup screens at
any time, press the Scroll and “-“ buttons
at the same time.
This is the initial setup screen. It indicates
that all items below it pertain to the heater
setup.
This screen indicates the hardware to the
controller. It will say “Res”.
This screen turns the process protection off
and on. The HTC is shipped with this
function set to “On” unless the HTC is
sold with an HAD.
For HAD and “W” dryer models only.
This screen turns the setback “On” or
“Off”. The HTC is shipped with function
set to “On” if the setback option is
installed.
This screen lets you access the Test
Mode.To access the test mode screens,
press "+" button when you are in the test
screen.
To get out of the test mode screens
a
t any time, press the Scroll and "-" but-
tons at the same time.
This screen returns the control board to the
f
actor
y def
ault settings (not necessar
ily for
a specif
ic model). Conair does not r
ecom
-
mend using this function unless instr
ucted
to b
y a Conair Ser
vice
T
echnician.
Set
uP
tyP
Res
Prt
ON
Stb
OFF
tSt
OFF
Ld.d
OFF
The setting on screen 42
should not be changed with-
out the direction of Conair
Service Personnel.