5.3 Electrical connection
The granulator should be connected up by an authorised electrician.
• Connect the granulator to the mains supply. See Electrical scheme, chapter
9, connecting (Q1).
Check the granulator motor’s rotation direction as follows:
• Set the main circuit-breaker on the control box to position (1) = “On”.
• Check that the emergency stop switch is not activated. It can be reset by
turning the knob in the direction of the arrow (anti-clockwise).
• Check that the break screws to the
screenbox's and hopper's safety switches
are completely tightened.
• Press in the “START” push-button.
• Check that the granulator motor’s
rotation direction is consistent with the
arrow on the hood.
If a blower is connected, check that its
rotation direction is consistent with the
arrow on the blower hood.
If the rotation direction is not correct:
• Change the incoming phases.