5.3 Electrical connection
The granulator should be connected up by an authorised electrician.
Connect the granulator to the mains supply. See Electrical scheme, chapter
9, connecting (Q1).
Check the granulator motor’s rotation direction as follows:
Set the main circuit-breaker on the control box to position (1) = “On”.
Check that the emergency stop switch is not activated. It can be reset by
turning the knob in the direction of the arrow (anti-clockwise).
Check that the break screws to the
screenbox's and hopper's safety switches
are completely tightened.
Press in the “START” push-button.
Check that the granulator motor’s
rotation direction is consistent with the
arrow on the hood.
If a blower is connected, check that its
rotation direction is consistent with the
arrow on the blower hood.
If the rotation direction is not correct:
Change the incoming phases.