Troubleshooting
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Lift does not respond
No Power to Mount
12V trigger option being
used
Overheated motor
Verify Power to Mount
Normal Operation
See "Low Voltage Sensing" section
Allow motor to cool for 10 to 15
minutes
SW1
Switch 1 IR
Switch 2 IR
Switch 3 IR
Switch 4 Not Used
Switch 5 Not Used
Switch 6 485 Address
Switch 7 485 Address
Switch 8 485 Address
IR System Code Select Logic
Switch Settings (Sw 1-3)
Select 2 Select 1 Select 0 IR System Code
OFF OFF OFF 6E
OFF OFF ON E1
OFF ON OFF E2
OFF ON ON E3
ON OFF OFF E4
ON OFF ON E5
ON ON OFF E6
ON ON ON E7
RS485 Address Select Logic
Switch Settings (Sw 6-8)
Select 2 Select 1 Select 0 RS485 Network
Address
OFF OFF OFF 00
OFF OFF ON 01
OFF ON OFF 02
OFF ON ON 03
ON OFF OFF 04
ON OFF ON 05
ON ON OFF 06
ON ON ON 07