Chief Manufacturing CM2L40 Indoor Furnishings User Manual


 
CM2L40 Installation Instructions
10
NOTE: With the mount configured for the display and the
display installed, it is now possible to calculate the
minimum I.D of the cabinet.
Determining Minimum I.D. of Furniture
1. Measure and record distance "A". (See Figure 16)
2. Measure and record distance "B". This is the material
thickness of the cover that will be mounted to the CM2. (See
Figure 16)
3. Add measurements from Steps 1 and 2 together. The total
is the minimum inside height of the furniture.
4. Measure and record distance "C". This dimension is from
the back side of the CM2 vertical mounting bracket to the
furthest point forward on the display. (See Figure 16)
CAUTION: IMPROPER FIT TOLERANCES CAN CAUSE
AREAS OF MOUNT OR FURNITURE TO COLLIDE WHEN
OPERATING THE MOUNT CAUSING SERIOUS DAMAGE
TO EQUIPMENT! Always provide for adequate tolerances
when building cabinet especially between base and cover.
(See Figure 15)
Figure 15
WARNING: EXCEEDING STATED WEIGHT LIMITS OF
THE CM2 CAN LEAD TO SERIOUS PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! The weight of furniture cover
must be calculated into the total weight being placed on the
mount; a total not to exceed 190 lbs (86.18 kg) the maximum
capacity of the CM2.
Cover
Base
Figure 16
A
B
C
C