Vermont Casting MSZ-D36NA Air Conditioner User Manual


 
OPERATING PROCEDURE
PHOTOS
6. Removing the line flow fan and the indoor fan motor
(1) Remove the panel and the corner box. (Refer to 1.)
(2) Remove the electrical box. (Refer to 2.)
(3) Remove the nozzle assembly. (Refer to 3.)
(4) Remove the water cover.
(5) Loosen the screw of the line flow fan.
(6) Remove the screws of the motor bed.
(7) Remove the lead wire of the indoor coil thermistor from the
hooks of the motor bed.
(8) Remove the motor band and the motor bed together with
indoor fan motor. (Be careful not to drop the indoor fan
motor because it is heavy.)
(9) Remove the screw of the motor band, and remove the
motor band then pull out the indoor fan motor.
(10)
Remove the screws of the left side of the heat exchanger.
(11)
Lift the left side of the heat exchanger.
(12)
Remove the line flow fan to the lower-left.
Photo 7
Screws of the motor bed
Screw of the motor band
Photo 8
Screws of the left
side of the heat
exchanger
Photo 9
Screw of the line
flow fan
Lead wire of the indoor
coil thermistor
33