Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont)
UNIT
50PG
NOMINAL
POWER
SUPPLY
VOLTS-PH-HZ
VOLTAGE
RANGE
COMPRESSOR
(EA)
OFM
FLA
IFM
FLA
POWER
EXHAUST
FLA
IFM
TYPE
ELECTRIC HEAT POWER SUPPLY
CRSINGLE
PART
NO.
(NOTE3)
DISCONNECT SIZE
WIRING
FIG.
NO.
MIN MAX RLA LRA
CRHEATER
PART
NO.
FLA
NOMINAL
KW*
MCA MOCP† FLA LRA
05
(cont)
208/230-3-60
(cont)
187 253 14.6 91 0.9
4.9
1.4
Low
Ċ Ċ Ċ/Ċ 30.2/30.2 40/40 Ċ 31/31 111/111 Ċ
208A00 10.0/11.5 3.8/5.0 30.2/30.2 40/40 030A00 31/31 111/111 15
209A00 15.0/17.3 5.6/7.5 32.6/35.0 40/40 030A00 31/33 111/111 15
210A00 20.0/23.1 7.5/10.0 38.9/42.2 40/45 030A00 36/39 111/111 15
211A00 30.0/34.6 11.3/15.0 51.4/56.6 60/60 030A00 47/53 111/111 15
212A00 40.0/46.2 15.0/20.0 63.9/71.0 70/80 031A00 59/66 111/111 16
5.2 High
Ċ Ċ Ċ/Ċ 30.5/30.5 45/45 Ċ 31/31 130/130 Ċ
208A00 10.0/11.5 3.8/5.0 30.5/30.5 45/45 030A00 31/31 130/130 15
209A00 15.0/17.3 5.6/7.5 33.0/35.3 45/45 030A00 31/33 130/130 15
210A00 20.0/23.1 7.5/10.0 39.3/42.6 45/45 030A00 36/40 130/130 15
211A00 30.0/34.6 11.3/15.0 51.8/57.0 60/60 030A00 48/53 130/130 15
212A00 40.0/46.2 15.0/20.0 64.3/71.4 70/80 031A00 59/66 130/130 16
460-3-60 414 506 7.1 46 0.5
2.1
Ċ
Low
Ċ Ċ Ċ 13.6 20 Ċ 14 55 Ċ
215A00 5.8 5.0 13.6 20 030A00 14 55 15
216A00 8.7 7.5 16.2 20 030A00 15 55 15
217A00 11.5 10.0 19.8 20 030A00 18 55 15
218A00 17.3 15.0 27.0 30 030A00 25 55 15
219A00 23.1 20.0 34.2 35 030A00 31 55 15
2.6 High
Ċ Ċ Ċ 14.1 20 Ċ 14 64 Ċ
215A00 5.8 5.0 14.1 20 030A00 14 64 15
216A00 8.7 7.5 16.8 20 030A00 15 64 15
217A00 11.5 10.0 20.4 25 030A00 19 64 15
218A00 17.3 15.0 27.6 30 030A00 25 64 15
219A00 23.1 20.0 34.8 35 030A00 32 64 15
2.1
0.6
Low
Ċ Ċ Ċ 14.2 20 Ċ 14 56 Ċ
215A00 5.8 5.0 14.2 20 030A00 14 56 15
216A00 8.7 7.5 16.9 20 030A00 16 56 15
217A00 11.5 10.0 20.5 25 030A00 19 56 15
218A00 17.3 15.0 27.7 30 030A00 26 56 15
219A00 23.1 20.0 35.0 40 030A00 32 56 15
2.6 High
Ċ Ċ Ċ 14.7 20 Ċ 15 65 Ċ
215A00 5.8 5.0 14.7 20 030A00 15 65 15
216A00 8.7 7.5 17.5 20 030A00 16 65 15
217A00 11.5 10.0 21.2 25 030A00 19 65 15
218A00 17.3 15.0 28.4 30 030A00 26 65 15
219A00 23.1 20.0 35.6 40 030A00 33 65 15
575-3-60 518 632 5.0 34.0 0.4 2.0
Ċ
Low
Ċ Ċ Ċ 10.7 15 Ċ 11 42 Ċ
221A00 9.2 10.0 16.3 20 030A00 15 42 15
222A00 13.9 15.0 22.1 25 030A00 20 42 15
223A00 18.5 20.0 27.9 30 030A00 26 42 15
High
Ċ Ċ Ċ 10.6 15 Ċ 11 48 Ċ
221A00 9.2 10.0 16.1 20 030A00 15 48 15
222A00 13.9 15.0 22.0 25 030A00 20 48 15
223A00 18.5 20.0 27.8 30 030A00 26 48 15
1.4
Low
Ċ Ċ Ċ 12.1 15 Ċ 12 44 Ċ
221A00 9.2 10.0 18.0 20 030A00 17 44 15
222A00 13.9 15.0 23.9 25 030A00 22 44 15
223A00 18.5 20.0 29.6 30 030A00 27 44 15
High
Ċ Ċ Ċ 12.0 15 Ċ 12 50 Ċ
221A00 9.2 10.0 17.9 20 030A00 16 50 15
222A00 13.9 15.0 23.8 25 030A00 22 50 15
223A00 18.5 20.0 29.5 30 030A00 27 50 15
06 208/230-1-60 187 253 26.9 145 1.5
4.9
Ċ
Low
Ċ Ċ Ċ/Ċ 46.1/46.1 60/60 Ċ 44/44 164/164 Ċ
201A00 17.3/20.0 3.8/5.0 46.1/46.1 60/60 028A00 44/44 164/164 13
202A00 26.0/30.0 5.6/7.5 46.1/48.6 60/60 028A00 44/46 164/164 13
203A00 34.7/40.0 7.5/10.0 54.5/61.1 60/70 028A00 51/57 164/164 13
204A00 52.0/60.0 11.3/15.0 76.1/86.1 80/90 029A00 71/80 164/164 14
205A00 69.3/80.0 15.0/20.0 97.8/111.1 100/125 029A00 91/103 164/164 14
206A00 86.7/100.0 18.8/25.0 119.4/136.1 125/150 029A00 111/126 164/164 14
7.0 High
Ċ Ċ Ċ/Ċ 48.2/48.2 60/60 Ċ 46/46 190/190 Ċ
201A00 17.3/20.0 3.8/5.0 48.2/48.2 60/60 028A00 46/46 190/190 13
202A00 26.0/30.0 5.6/7.5 48.2/51.3 60/60 028A00 46/48 190/190 13
203A00 34.7/40.0 7.5/10.0 57.1/63.8 60/70 028A00 53/60 190/190 13
204A00 52.0/60.0 11.3/15.0 78.7/88.8 80/90 029A00 73/83 190/190 14
205A00 69.3/80.0 15.0/20.0 100.4/113.8 110/125 029A00 93/106 190/190 14
206A00 86.7/100.0 18.8/25.0 122.1/138.8 125/150 029A00 113/129 190/190 14
LEGEND
FLA − Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
IFM Indoor − Fan Motor
LRA Locked Rotor Amps
MCA Minimum Circuit Amps
MOCP Maximum Overcurrent Protection
NEC National Electrical Code
OFM Outdoor−Fan Motor
RLA Rated Load Amps
* Heater capacity (kW) is based on heater voltage of 208 v, 240 v, or 480 v. If power distribu-
tion voltage to unit varies from rated heater voltage, heater kW will vary accordingly.
Fuse or HACR circuit breaker.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equip-
ment (refer to NEC Articles 430 and 440), the overcurrent protective device for the
unit shall be fuse or HACR breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than
2%. Use the following formula to determine the percentage of voltage imbalance.
% Voltage Imbalance = 100 x
max voltage deviation from average voltage
average voltage
Example: Supply voltage is 460-3-60
AB = 224 v
BC = 231 v
AC = 226 v
Average Voltage =
224 + 231 + 226
3
681
3
=
227
=
Determine maximum deviation from average voltage.
(AB) 227 – 223 = 3 v
(BC) 231 – 227 = 4 v
(AC) 227 – 226 = 1 v
Maximum deviation is 4 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x
4
227
= 1.76%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric
utility company immediately.
3. Single point kits CRSINGLE028A00 and CRSINGLE030A00 are not required if
field−supplied pressure connectors are used.
50PG03−16