Table 4C -- Physical Data, 38BK009,012 Outdoor Heat Pump Units*
UNIT 38BK
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (Ib)
REFRIGERANT TYPE
Control (Cooling)
Control (Heating)
Factory Charge (Ib)
COMPRESSOR TYPE
Model
Oil (Recharge) (oz)
CRANKCASE HEATER (Watts)
OUTDOOR FAN
Rpm
Diameter (in,),..No. of Blades
Motor Wafts
Nominal Air Cfm
OUTDOOR COIL
Face Area (sq ft)...No, of Rows
Finslln.
CONTROLS
Fusible Plug
Accumulator
Defrost Method
Control Voltage
REFRIGERANT LINES
Connection l_jpe
Liquid Line OD (in.)
Vapor Line OD (in.)
Maximum Length (ft)
Maximum Lift (Fan Coil Above) (ft)
Maximum Lift (Fan Coil Below) (ft)
*These units may only be used with40QNF-./H fan coil units.
009 012
1
60,7 66.5
R-22
AccuRatar _ Pistonat Outdoor Unit
AccuRater Pistonat Outdoor Unit
1.5 I 2.0
Carder Hermetic Rotary
EBA095111H10.1 I EBC130111H10.1
40
Propeller, Direct Drive
850
12¼...4
87
756
850
121/4._4
87
756
Fin
3.5...2
17
3.5._118 Copper Tube, Aluminum
210 F 210 F
Yes Yes
Demand Demand
115 v 230 v
Male Flare
¼ ¼
½ ½
35 35
16 16
30 30