Carrier 38AN,BK Heat Pump User Manual


 
Table 4A-- Physical Data, 38AN Cooling Only Condensing Units*
UNIT 38AN
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (Ib)
REFRIGERANT TYPE
Control (Cooling)
Factory Charge (Ib)
COMPRESSOR TYPE
Model
Oil (Recharge) (oz)
Crankcase Heater
Accumulator
OUTDOOR FAN
Rpm
Diameter (in.)...No. of Blades
Motor Watts
Nominal Air Cfm
OUTDOOR COIL
Face Area (sq tt),..No, of Rows
Fins/In,
CONTROLS
Fusible Plug (F)
Control Voltage
REFRIGERANT LINES
Connection Type
Liquid Line OD (in,)
Vapor Line OD (in,)
Maximum Length (ft)
Maximum Lift Fan Coil (Above Outdoor) (ft)
Maximum Lift Fan Coil (Below Outdoor) (ft)
*These units may only be used with 40QNB009,012 fan coil units
009 012
¾ 1
55 62
R-22
Capilla_ Tube
1.5 1.8
Carrier Hermetic Rotary
EAA090111A10.1 I EBB120111A10.1
None
Yes
850 Propeller, iirect Drive 850
12¼...4 12¼...4
87 87
750 750
Copper Tube, Aluminum Fin
3.5...1 3.5...2
18 17
210 210
115 230
Male Flare
¼ ¼
½ ½
35 35
16 16
30 30
Table 4B -- Physical Data, 40QNB Cooling Only High Wall Units
UNIT 40QNB 009* 012"
NOMINAL CAPACITY (Tons) ¥4 1
NOMINAL SIZE (Btuh) 9000 12,000
OPERATING WEIGHT (Ib) 18.7 24.2
MOISTURE REMOVAL RATE (Pints/Hr) 2.4 3.4
FINISH White
REFRIGERANT R-22
Control (Cooling) Capillary Tube in Outdoor Unit
Factory or System Charge (Ib)t 1.5 I 1,8
INDOOR FAN Direct Drive Centrifugal
Rpm..,Cfm High 1200,,.240 1040...260
Rpm..,Cfm Medium 1100..,210 940,,,240
Rpm...Cfm Low 1000,..180 850,,,210
Motor Watts 34 35
Blowers -- No...,Size (in.) 1,..3.54 x 27.75 1,,,3,94 x 27.75
INDOOR COIL Copper Tube, Aluminum Fin
Face Area (sq ft) 1.45 t6
No. of Rows 2 2
Fins/in, 18 17
Circuits 2 3
FILTERS Cleanable
(Quantity) Size (in.) (2) 9 x 12 I (2) 9_,_x 13_A
AIRSWEEP
Horizontal Manual
Vertical Automatic
CONTROLS integrated Microprocessor
Remote Controller Wireless
Freeze Protection Yes
Auto. Restart Yes
Diagnostics Yes
Timer Mode 24-Hour Startup/Shutdown Type
Test Mode Yes
Dehumidification Mode Yes
Fan Mode HighlMediumlLowlAuto.
Control Voltage 115 v I 230 v
REFRIGERANT LINES
Connection Type Male Flare
Liquid Line OD (in.) ¼ ¼
Vapor Line OD (in.) ½ _,_
Maximum Length (ft) 35 35
Maximum Lift Fan Coil (Above Outdoor)(ft) 16 16
Maximum Lift Fan Coil (Below Outdoor) (ft) 30 30
CONDENSATE DRAIN CONNECTION (in.) % OD, 7/_8ID
*Units may onlybe matched with 38AN outdoorunits.
1"Fullfactory charge shipped in outdoorunit. Charge is determined based on 25 ft of line.
4