Canon GC-251 Indoor Furnishings User Manual


 
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
77
Parameter ID 34
Parameter
Name
Deceleration Time
Data Deceleration time (Unit: ms)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the deceleration time for a stop by “Command ID = 9:
Forced Stop.”
Related
Command
/Parameter
Forced Stop (Command ID = 9)
Parameter ID 36
Parameter
Name
Out-position width
Data Out-position (Unit: pulse)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation An error is output if a difference from the target value exceeds the setting of this
parameter becoming static.
Setting 0 is invalid.
Related
Command
/Parameter
Bit 13 “Current Saturation” becomes 1 in error read (Command ID = 15).
Parameter ID 40
Parameter
Name
Feed-forward Gain
Data Feed-forward gain (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the feed-forward gain. This is usually set at shipping.
Setting 0 disables feed-forward.
Related
Command
/Parameter
Parameter ID 42
Parameter
Name
Overshoot Control
Data Overshoot Control (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set pole rearrangement. This is usually set at shipping.
Setting 100 disables pole rearrangement.
Related
Command
/Parameter