CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
22
(Target Position Data) XDAT YDAT
The data length of the target position data by the high-speed serial communication can be
changed by two following parameters.
The target position data length can be changed in 16bit – 20bit.
Parameter ID DATA
16 16bit Data
17 17bit Data
18 18bit Data
19 19bit Data
20 20bit Data
The least significant bit position of the target position data of high-speed serial communication
20bit data can be set by following parameter.
The right shifts this number of bit make the target position data.
Parameter ID DATA
0 0bit position
1 1bit position
2 2bit position
3 3bit position
4 4bit position
An example of the setting as follows.
Parameter ID = 67 16
Parameter ID = 68 1
Parameter ID = 67 18
Parameter ID = 68 2