Cal Flame BBQ11955P Burner User Manual


 
6
Installation / Assembly
Power Burner
LTR50001100, Rev. A
www.calamebbq.com
LP Gas
Tank Requirements
For plumbed-in LP installation, use a convertible regulator and set it
for LP gas.
Maximum line pressure for plumbed-in propane is 14” WC (3.5 kPa).
Minimum line pressure for propane is 11” WC.
The Power Burner must be used with the gas pressure regulator. The
regulator will control and maintain a uniform gas pressure in the mani-
fold. The burner orices have been sized for the gas pressure delivered
by the regulator.
WARNING: Attempting to operate the Power Burner without the gas
regulator installed could cause an explosion and possible death.
Cylinder Specication
Any LP gas supply cylinder used with the Power Burner must be:
Constructed and marked in accordance with the Specications
for LP-Gas Cylinders of the U.S. Department of Transportation
or the National Standard of Canada, CAN/CSA-B339, Cylin-
ders, Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable.
Approximately 12 inches in diameter and 18 inches high.