Appendix
25
Power Burner
LTR50001100, Rev. A
www.calamebbq.com
Problem: Misalignment of Igniter on Burner
Solution: Check for proper position of the electrode tip, which •
should be pointing forward towards the front of the
burner and free of grease to allow proper sparking.
The ignition wire should be connected rmly to the •
valve ignition device and electrode. Replace the ig-
nition wire if it is frayed or cracked.
With the gas supply closed and all control knobs set •
to the off position, check each position igniter indi-
vidually for the presence of a spark at the electrode.
Push each knob in fully and rotate it about 1/4 turn
to the left (counter-clockwise) until you hear a loud
click. The trigger hitting the strike block should
produce a blue spark at the electrode tip. Return
control knob to the off position before checking the
next igniter.
While the Power Burner is still hot, wait for a mini-•
mum of ve minutes before commencing re-ignition.
(This allows accumulated gas fumes to clear.) If all
checks / corrections have been made and the Power
Burner still fails to operate properly, contact your lo-
cal Cal Flame dealer.
Problem: Flashback
Solution: When re occurs in and around the burner tubes, im-
mediately turn off gas at its source and turn the con-
trol knobs clockwise to the ‘OFF’ position. Wait until the
Power Burner has cooled off and then clean the burner
tubes and burners as described on page of this manu-
al.