Appendix
23
Power Burner
LTR50001100, Rev. A
www.calamebbq.com
Troubleshooting
Problem: Smell of gas is present
Solution: Check for loose connections in the gas line. Perform a
leak test following the procedure on page 9.
Problem: Burner does not ignite
Solution: Use the following procedure with the gure below.
Check the position of the sparker tip. It should be point-
ing forward towards the front of the burner.
Make sure there is a blue spark at the electrode tip •
to the burner.
Make sure the igniter wire is connected rmly to the •
valve ignition device and the electrode.
Make sure the valve orice is free of any debris, dust •
or grease.
Make sure the valve orice is aligned inside the front •
hole of the burner.
If there is no spark at all, replace the electrode or •
igniter wire.
Note: Turn off the gas at the source while troubleshoot-
ing.
Appendix