New Buck Corporation CR8T Indoor Fireplace User Manual


 
“WARNING: THIS APPLIANCE IS FOR INSTALLATION ONLY IN A SOLID
FUEL BURNING MASONRY OR UL127 FACTORY BUILT FIREPLACE OR IN A
LISTED VENTLESS FIREBOX ENCLOSURE.
IT HAS BEEN DESIGN CERTIFIED FOR THESE INSTALLATIONS . EXCEPTION:
DO NOT INSTALL THIS APPLIANCE IN A FACTORY BUILT FIREPLACE THAT IN-
CLUDES INSTRUCTIONS STATING IT HAS NOT BEEN TESTED OR SHOULD NOT BE
USED WITH UNVENTED GAS LOGS”.
INSTALLATION AND CLEARANCES
To ensure a safe installation into an existing solid fuel burning fireplace, the following
instructions must be carefully followed.
NOTE: Gas control knobs are located in lower front center of base. “OFF/PILOT/ON” Right knob ,
Thermostat adjustment is the Left knob..
1. Side wall Clearances:
Clearance from the right and left side of the fireplace opening to any adjacent com-
bustible wall should not be less than 12”.
2. Ceiling Clearance:
The ceiling height should not be less than 42” from the top of the fireplace opening.
3. Mantel Clearance:
Clearances from top of heater to mantel or mantel supports. See Figure 1.
4. Front Clearances:
No objects should be placed within 24” from the front of the fireplace opening.
MINIMUM FIREPLACE DIMENSIONS FOR CR8T LOG SET MANUFACTURED BY
NEW BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MASONRY
FIREPLACE AND PREFAB OR MANUFACTURED FIREPLACES.
NOTE: When using CR8T log set with the Model 19HS heat shield see page 14 for
clearances.
MODEL HEIGHT OF WIDTH OF WIDTH AT DEPTH OF
OPENING OPENING REAR FIREPLACE
AT FRONT
CR8T 17” 24” 18” 10”
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.
WARNING: ‘ CUTTING ANY SHEET METAL PARTS OF THE SOLID-FUEL BURN-
ING FIREPLACE OR LISTED VENTLESS FIREBOX ENCLOSURE IN WHICH THE
UNVENTED FIREPLACE INSERT (LOG SET) IS TO BE INSTALLED IS PROHIB-
ITED.”
NOTE: “Smoke shelves, shields and baffles may be removed if attached by mechanical fasten-
ers.”
NOTE: ”Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applica-
ble) can be removed from the fireplace before installing the unvented fireplace insert.”
5