New Buck Corporation CR8T Indoor Fireplace User Manual


 
SECTION III
INSTALLATION OF LOG SET WITH
(OPTION ) HEAT SHIELD MODEL 19HS
For installation of gas supply see “Fireplace and Gas Connection” Page 6, Section II.
NOTE: The same clearances for the log set are also used with the 19 Heat Shield.
See Page 4, Section II, Figure 1.
NOTE: Centrally locate the Heat Shield in the fireplace and place it deep enough into the
fireplace to accomplish adequate draft (if use as a vented heater is planned). Ensure that the
Heat Shield front is inside the front edge of the fireplace , see Figure 5. Using the screws
and anchors provided , fasten the Heat Shield to the floor of the fireplace. On each side of
floor frame of the Heat Shield base, there is a “go through hole”. Position the Heat Shield
as described above. Mark the hole for drilling. See Figure 5.
NOTE: When using CR8T LOG SET with optional Heat Shield the following minimums
must be met.
FRONT 24” REAR 23” HEIGHT 20” DEPTH 19 1/2”
Follow log positioning in Section II.
NOTE: For the first few hours of burning, you will have paint and burning smell. It
is recommended to leave the fan off during this period. You may also want to raise a
window or open the doors.
Area For Log
Base Placement
(Center)
Flush”
Blower Motor
Floor Frame (s)
“Go Through Holes” for fastening the 19HS
to the floor.
Fireplace
Heat Shield
Mantel
Figure 5
14