New Buck Corporation CR8T Indoor Fireplace User Manual


 
SECTION II
RESIDENTIAL INSTALLATION OF GAS LOGS
FIREPLACE PREPARATION
The fireplace needs to be prepared before installing the gas logs.
A. Turn off the gas supply to the fireplace.
B. Any outside air ducts on the fireplace shall be permanently closed at the time of the
appliance installation.
“WARNING: BEFORE INSTALLING IN A SOLID FUEL BURNING FIREPLACE,
THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT,
CREOSOTE, ASHES AND LOOSE PAINT BY A QUALIFIED CHIMNEY
CLEANER”.
“WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO
THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME
PATTERN”.
LOCATION
Centrally locate the gas logs in the fireplace. Place them deep enough into the fireplace to
accomplish adequate draft (if use as a vented gas log set is planned). Ensure that front of the
logs sit inside the edge of the fireplace.
NOTE: IF THE EXISTING FIREPLACE IE EQUIPPED WITH A SCREEN IT MUST
BE IN PLACE WHEN THE APPLIANCE IS OPERATING . THE SCREEN SHALL
HAVE ADEQUATE OPENING (S) FOR INTRODUCTION OF COMBUSTION AND
VENTILATION AIR.
NOTE: MAINTAIN PROPER CLEARANCE FOR PURPOSE OF SERVICING,
PROPER INSTALLATION, AND OPERATION.
Mantel minimum clearances
for a listed Zero Clearance
Firebox or a Masonry Fire-
place.
*WARNING: Canopy
model MAPSFPC must be
used at all times unless a
10-inch mantel is installed
at 36-inches above the fire-
place opening. (Can be ob-
tained from your local
dealer or purchased from
the factory.)
ANGLE MANTEL
FLAT MANTEL
FIGURE 1
Top of firebox opening
2.5”
14”
18”
20”
10” TO 12” Out From Wall
6” To 10” Out From Wall
0” To 6” Out From Wall
MAX. OF 2 1/2”
Top of firebox
opening
10”
12”
14”
8” TO 10” OUT FROM WALL
6” TO 8” OUT FROM WALL
0” TO 6” OUT FROM WALL
2.5”
16”
10” TO 12” OUT FROM WALL
4