New Buck Corporation CR8T Indoor Fireplace User Manual


 
GAS CONNECTION
Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of
gas listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your
dealer for proper model.
Always use an external regulator for all LP heaters to reduce the supply tank pressure to a
maximum of 13” W.C. This is in addition to the regulator furnished with the heater.
Warning: Connection directly to an unregulated LP tank can cause an
explosion.
The normal gas connection is 3/8” N.P.T. made at the right side facing the log set. If a
left side connection is desired, the connecting pipe may be routed under the rear of the
burner base to terminate at the right hand side for connection to the inlet of the valve.
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural
gas. Test for leaks using a solution of soap and water after completing the connection.
DO NOT USE OPEN FLAME.
NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of
1.5 inch (37.5mm) diameter or less may be drilled through the lower sides or bottom of the
firebox in a proper workmanlike manner. This access hole must be plugged with non-
combustible insulation after gas supply line has been installed.”
PREPARING LOG KIT
Open the cartons containing the Burner Base and the Logs. Inside one of the cartons you will find the
Burner Base. The Logs are boxed separately.
CR8T (1) REAR LOG (2) FRONT LOG (3) LEFT TOP LOG
WAR N I N G: POSITIONING OF LOGS IS VERY CRITICAL (FIGURE 2).
LOG PLACEMENT FOR CR8T LOG SET.
1. Place Rear log #1 on rear log support. The log has alignment notche on Left and
right corners.
2. Place Front log #2 with alignment notches over front andirons.
3. Left Top log has locating hole in one end, place hole over pin on Left side of Rear log
(#1) . Make sure Front of Left Top log (#3) is resting on Left side of Left Andiron.
Solid fuels shall not be burned in the same fireplace where an unvented room heater has been
installed.
NOTE: The following label has been provided with this appliance and must be read and then
attached to the floor of the fireplace firebox area beneath the appliance. The label is a peel and
stick label. Make sure the area is cleaned before attaching the label to it.
“WARNING: This solid-fuel burning fireplace or listed ventless enclosure has been
converted for use with an unvented fireplace insert only. A solid-fuel burning fireplace
cannot be used for burning wood or solid fuels unless all original parts have been re-
placed, and the fireplace re-approved by the authority having jurisdiction. A ventless
firebox enclosure cannot be used with an unvented gas log unless all original parts have
been replaced, and the ventless firebox enclosure re-approved by the authority having
jurisdiction.”
6