New Buck Corporation CR8T Indoor Fireplace User Manual


 
4. Air in gas lines when 4. Continue to hold down control
installed knob. Repeat igniting
operation until air is removed.
5. Depleted gas supply 5. Contact local propane gas company
6. ODS/PILOT is clogged 6. Clean ODS/PILOT or replace
ODS/PILOT assembly
7. Gas regulator setting is 7. Replace gas regulator
not correct
OBSERVED POSSIBLE
PROBLEM PROBLEM SOLUTION
ODS/PILOT lights but flame 1. Control knob is not fully 1. Press in control knob
goes out when control knob is pressed in completely
released 2. Control knob not pressed in 2. After ODS/PILOT lights keep
long enough control knob pressed in 30
seconds
3. Safety interlock system has 3. Wait 1 minute for safety
been triggered ( if equipped) interlock system to reset
4. Manual shutoff valve not 4. Fully open manual shutoff
fully open valve
5. Thermocouple connection 5. Hand tighten until snug, then
loose at control valve tighten 1/4 turn
6. Pilot flame not touching 6. A) Contact local propane gas
thermocouple, which allows company
thermocouple to cool, causing B) Clean ODS/PILOT (See
pilot flame to go out. This Cleaning and Maintenance),
problem can be caused by one or replace ODS/PILOT
or both of the following: assembly
A) low gas pressure
B) dirty or partially
clogged ODS/PILOT
7. Control valve damaged 7. Replace control valve
27