New Buck Corporation GAS STOVE HEATER Stove User Manual


 
Installation must include an equipment
shutoff valve, union, and plugged 1/8"
NPT tap. Locate NPT tap within reach
for test gauge hook up. NPT tap must
be upstream from heater (See Figure
18, BVFB series).
IMPORTANT: Install equipment
shutoff valve in an accessible location.
The equipment shutoff valve is for
turning on or shutting off the gas to the
appliance.
Apply pipe joint sealant lightly to male
threads. This will prevent excess
sealant from going into pipe. Excess
sealant in pipe could result in clogged
heater valves.
CAUTION: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
INSTALLATION
Continued
CONNECTING TO GAS
SUPPLY
WARNING: This appliance is
equipped with a 3/8
" NPT
(National Pipe Thread) inlet
connection to the pressure
regulator.
WARNING: A qualified service
person must connect heater to gas
supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you
have the items listed below:
piping (check local codes)
sealant (resistant to LP gas)
equipment shutoff valve
tests gauge connection
sediment trap
tee joint
pipe wrench
A CSA/AGA design-certified equip-
ment shutoff valve with 1/8" NPT tap is
an acceptable alternative to test gauge
connection. Purchase the optional CSA/
AGA design-certified equipment
shutoff valve from your dealer. See
Accessories, page 23.
The gas inlet connection for the stove
heater is located on the lower right-
hand side when viewed from the front
of the unit. The gas connection can be
made either through the bottom right
side or through the lower back opening
as illustrated in Figure 17. Make sure
gas log heater is secured to the stove
cavity assembly.
WARNING: Never connect
heater to private (non-utility) gas
wells. This gas is commonly
known as wellhead gas.
CAUTION: Use only new, black
iron or steel pipe. Internally-
tinned copper tubing may be used
in certain areas. Check your local
codes. Use pipe of 1/2
" diameter
or greater to allow proper gas
volume to heater.
BACK VIEW
BACK STOVE
PANEL
SIDE VIEW
FRONT
OF
STOVE
UNIT
GAS
INLET
CONNEC-
TION
ACCESS
FIGURE 17 - GAS REGULATOR LOCATION AND GAS LINE ACCESS INTO
STOVE CABINET
FIGURE 18 - GAS CONNECTION
Approved Flexible Gas
Hose (if allowed by local
codes)
Gas Control
CSA/AGA Design-
Certified Equipment
Shutoff Valve With
1/8” NPT Tap
From Gas Meter
(5” W.C.**to 10.5”
W.C. Pressure)
Tee Joint
Pipe Nipple
Cap
Sediment
Trap
3” Minimum
14