New Buck Corporation DV23ZC Indoor Fireplace User Manual


 
GENERAL INFORMATION
LOCATION AND CLEARANCE
Make sure your installation location provides adequate combustion and ventilation air.
In selecting the location, the aesthetic and functional uses of the appliance are primary concerns.
However, vent system routing to the exterior and access to the fuel supply are also important.
Consideration should be given to traffic ways, furniture, draperies, etc., due to elevated surface
temperatures. The location should also be free of electrical, plumbing or other heating/air con-
ditioning ducts. Be sure to maintain adequate clearances around air openings into combustion
chamber.
The appliance should be mounted on a fully supported base extending the full width and depth
of the unit. The appliance may be located on or near conventional construction materials.
However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or
wood barrier covering the entire bottom surface must be used.
Right and left sides of the unit are determined when standing in front of the unit.
Minimum clearance to combustibles: sides and back - 0", floor - 0" , adjacent wall to Front -
6".
Minimum clearance to combustibles for the vent system is 2" when passing through a wall or
chase.
ASSEMBLY STEPS—OVERVIEW
The typical sequence of installation follows. However, each installation is unique resulting in
variations to those described.
1. Construct framing and position the appliance.
2. Route gas supply line and bring in electrical service line to appliance location.
3. Install vent system.
4. Make connection to gas supply and electrical service.
5. Install the log assembly.
6. Install the remote thermostat (optional).
7. Test fire the burner.
8. Install glass panel.
9. Finish enclosure walls and trim.
5