New Buck Corporation DV1000 Indoor Fireplace User Manual


 
DATE
REV
.
DAT
E
REMOVABLE INNER BOTTOM PAN ASSEMBLY
The DV1000 is equip with a removable Inner Bottom Pan Assembly for service purposes only. The burner
control assembly should only be accessed by this procedure by a qualified service technician, or by the
manufacturer. Follow the instructions and diagrams below.
1. Turn gas OFF at equipment shut OFF
valve, and disconnect union located at
Right side of control valve. Remove
Cover Door, see pages 3 & 4.
2. Remove the 4 screws located on top of
the Burner Pan area which attach the
Burner Pan to the Firebox Deck.
3. Remove the 4 screws located at the
back of the Firebox area which attach
the Firebox Deck to the back of the
Firebox.
4. Lift the Firebox Deck upward and out-
wards. And then gently lift the Burner
and Ventura assembly upward from
top of the Orifice assembly.
5. Next locate the 26 screws pattern
around the edge of the Inner Bottom
Pan Assembly and remove them.
6. Push upward from the bottom of the
Inner Bottom Pan ( do not
2
3
4
push on the gas valve control or any of the other components).
7. A gasket is located on the bottom edges of the Inner Bottom
Pan assembly. If this gasket is damaged during this process it
must be replaced with a gasket from the manufacture and
resealed with high-temperature caulk weather damaged or
5
6
7
FIGURE 12
Page 15