HEAT PUMP HEATING PERFORMANCE continued
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDBEntering Dry Bulb
System Design
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature is 55°F (12.8°C).
3. Low-ambient operation accessory is not available.
4. Maximum outdoor operating air temperature is 125°F (51.7°C).
5. For reliable operation, unit should be level in all horizontal planes.
6. Maximum elevation of indoor coil above or below base of outdoor unit is; indoor coil above50 ft, indoor coil below150 ft.
7. For interconnecting refrigerant tube lengths greater than 50 ft, consult Application Guideline and Service ManualAir Conditioners and Heat
Pumps Using Puron® Refrigerant.
8. If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36-in.
may be buried without further considerations. Do not bury lines over 36 in.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
10. Must be installed with factory-supplied hard shutoff, balanced port TXV (eld installed).
11. Do not apply capillary tube indoor coils to these units.
12. Factory-supplied lter drier must be installed.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17 27 37 47 57 67
EDB CFM
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Total Int* KW Total Int* KW Total Int* KW Total Int* KW Total Int* KW Total Int* KW
698BNX060000 Outdoor Section With FV4ANB006 Indoor Section - Low Speed
65
1050 13.32 12.15 1.65 17.76 15.78 1.76 22.45 20.43 1.88 27.25 27.25 2.00 32.54 32.54 2.13 38.87 38.87 2.25
1350 13.89 12.66 1.67 18.53 16.46 1.78 23.38 21.28 1.89 28.36 28.36 1.99 34.36 34.36 2.08 37.51 37.51 2.14
1650 14.30 13.04 1.70 19.13 16.99 1.80 23.98 21.82 1.90 29.23 29.23 2.00 34.58 34.58 2.07 35.47 35.47 2.08
1950 14.90 13.59 1.73 19.49 17.31 1.82 24.51 22.31 1.92 29.73 29.73 2.02 33.27 33.27 2.05 33.44 33.44 2.05
2250 15.19 13.85 1.76 19.89 17.67 1.86 24.83 22.60 1.95 30.42 30.42 2.02 32.03 32.03 2.04 32.38 32.38 2.05
70
1050 12.49 11.39 1.68 16.78 14.90 1.80 21.42 19.49 1.93 26.22 26.22 2.06 31.40 31.40 2.19 37.53 37.53 2.31
1350 13.08 11.92 1.70 17.50 15.55 1.82 22.35 20.34 1.93 27.32 27.32 2.05 32.86 32.86 2.16 37.50 37.50 2.23
1650 13.50 12.31 1.73 18.02 16.00 1.84 23.00 20.93 1.95 28.05 28.05 2.05 34.03 34.03 2.14 35.81 35.81 2.17
1950 13.82 12.60 1.76 18.43 16.37 1.87 23.46 21.35 1.97 28.60 28.60 2.07 33.56 33.56 2.13 34.12 34.12 2.14
2250 14.10 12.85 1.80 18.75 16.65 1.90 23.86 21.71 2.00 29.09 29.09 2.10 32.69 32.69 2.13 33.28 33.28 2.14
75
1050 11.43 10.43 1.70 15.70 13.95 1.84 20.36 18.53 1.97 25.18 25.18 2.11 30.24 30.24 2.24 36.23 36.23 2.39
1350 12.02 10.96 1.73 16.46 14.62 1.85 21.28 19.36 1.98 26.27 26.27 2.10 31.59 31.59 2.22 37.75 37.75 2.33
1650 11.37 10.37 1.76 16.97 15.07 1.88 21.93 19.96 1.99 26.98 26.98 2.11 32.80 32.80 2.21 36.11 36.11 2.26
1950 12.73 11.61 1.79 17.36 15.42 1.91 22.40 20.39 2.02 27.52 27.52 2.13 33.36 33.36 2.22 34.63 34.63 2.23
2250 13.00 11.85 1.83 17.68 15.70 1.94 22.78 20.73 2.05 27.95 27.95 2.15 33.14 33.14 2.22 33.78 33.78 2.23
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 060 1.02 1.20 CK3BA 060 0.98 1.03
CC5A/CD5AB 060 1.02 1.20 CK5A/CK5BA 060 0.98 1.03
CC5A/CD5AW 060 1.04 1.19 CK5A/CK5BN 060 0.99 1.02
CE3AA 060 1.04 1.18 CK5A/CK5BT 060 0.98 1.03
CK3BA 060 1.04 1.18 CK5A/CK5BX 060 1.00 1.02
CK5A/CK5BA 060 1.04 1.18
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK5A/CK5BN 060 1.05 1.17 CC5A/CD5AA 060 0.98 1.06
CK5A/CK5BT 060 1.04 1.18 CC5A/CD5AB 060 0.98 1.06
CK5A/CK5BX 060 1.05 1.17 CC5A/CD5AW 060 1.00 1.04
FK4CNB 006 1.00 1.00 CE3AA 060 1.00 1.05
FV4ANB 006 1.00 1.00 CK3BA 060 1.00 1.05
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
CK5A/CK5BA 060 1.00 1.05
CC5A/CD5AA 060 0.97 1.04 CK5A/CK5BN 060 1.02 1.06
CC5A/CD5AB 060 0.97 1.04 CK5A/CK5BT 060 1.00 1.05
CC5A/CD5AW 060 0.98 1.01 CK5A/CK5BX 060 1.01 1.04
CE3AA 060 0.98 1.02
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CK3BA 060 0.98 1.03 CC5A/CD5AA 060 1.01 1.07
CK5A/CK5BA 060 0.98 1.03 CC5A/CD5AB 060 1.01 1.07
CK5A/CK5BN 060 0.99 1.02 CC5A/CD5AW 060 1.01 1.06
CK5A/CK5BT 060 0.98 1.03 CE3AA 060 1.00 1.05
CK5A/CK5BX 060 0.99 1.01 CK3BA 060 1.00 1.06
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
CK5A/CK5BA 060 1.00 1.06
CC5A/CD5AA 060 0.98 1.03 CK5A/CK5BN 060 1.01 1.04
CC5A/CD5AB 060 0.98 1.03 CK5A/CK5BT 060 1.00 1.06
CC5A/CD5AW 060 0.98 1.03 CK5A/CK5BX 060 1.01 1.04
CE3AA 060 0.98 1.03 ——