Bryant 698B Heat Pump User Manual


 
38
HEAT PUMP HEATING PERFORMANCE continued
See notes on page 41.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17 27 37 47 57 67
EDB CFM
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Total Int* KW Total Int* KW Total Int* KW Total Int* KW Total Int* KW Total Int* KW
698BNX048000 Outdoor Section With FV4ANF005 Indoor Section - Low Speed
65
850 13.14 11.98 1.53 16.54 14.69 1.64 20.48 18.64 1.77 24.67 24.67 1.91 29.26 29.26 2.06 34.43 34.43 2.26
1075 13.57 12.37 1.53 17.14 15.22 1.64 21.06 19.17 1.76 25.31 25.31 1.90 29.94 29.94 2.05 35.36 35.36 2.21
1300 13.88 12.65 1.55 17.50 15.54 1.65 21.42 19.49 1.77 25.66 25.66 1.91 30.25 30.25 2.06 35.45 35.45 2.20
1525 14.15 12.90 1.57 17.76 15.78 1.67 21.65 19.70 1.79 25.86 25.86 1.93 30.63 30.63 2.07 35.81 35.81 2.23
1750 14.35 13.08 1.59 17.97 15.96 1.69 21.82 19.85 1.81 26.02 26.02 1.95 30.85 30.85 2.08 35.89 35.89 2.24
70
850 12.53 11.43 1.56 15.93 14.15 1.68 19.74 17.96 1.81 23.91 23.91 1.95 28.50 28.50 2.12 33.58 33.58 2.32
1075 12.97 11.83 1.57 16.49 14.65 1.68 20.34 18.51 1.80 24.57 24.57 1.94 29.19 29.19 2.10 34.08 34.08 2.26
1300 13.26 12.09 1.58 16.88 14.99 1.69 20.80 18.93 1.82 24.93 24.93 1.95 29.54 29.54 2.11 34.87 34.87 2.27
1525 13.53 12.34 1.60 17.14 15.22 1.71 21.04 19.15 1.84 25.18 25.18 1.97 29.75 29.75 2.14 35.14 35.14 2.28
1750 13.75 12.54 1.62 17.35 15.41 1.73 21.20 19.29 1.86 25.35 25.35 2.00 30.00 30.00 2.14 35.00 35.00 2.30
75
850 11.91 10.86 1.60 15.32 13.60 1.72 19.05 17.34 1.86 23.19 23.19 2.01 27.70 27.70 2.17 32.70 32.70 2.37
1075 12.34 11.25 1.60 15.83 14.06 1.72 19.63 17.86 1.84 23.89 23.89 2.00 28.42 28.42 2.16 33.47 33.47 2.35
1300 12.66 11.54 1.62 16.20 14.39 1.73 20.03 18.23 1.85 24.25 24.25 2.00 28.78 28.78 2.17 34.02 34.02 2.33
1525 12.91 11.77 1.64 16.49 14.65 1.75 20.29 18.46 1.87 24.43 24.43 2.01 29.01 29.01 2.18 34.19 34.19 2.33
1750 13.10 11.94 1.66 16.71 14.84 1.76 20.53 18.68 1.89 24.69 24.69 2.04 29.17 29.17 2.21 34.31 34.31 2.35
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 060 1.00 1.17 CK5A/CK5BW 048 1.00 1.05
CC5A/CD5AB 060 1.00 1.17 CK5A/CK5BX 060 1.00 1.03
CC5A/CD5AC 048 1.00 1.16
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
CC5A/CD5AW 048 1.00 1.14 CC5A/CD5AA 060 1.00 1.04
060 1.00 1.13 CC5A/CD5AB 060 1.00 1.04
CD5AA 048 1.00 1.14 CC5A/CD5AC 048 1.00 1.06
CD5AB 048 1.00 1.14 CC5A/CD5AW 048 1.00 1.04
CE3AA 048 1.00 1.14 060 1.00 1.03
060 1.00 1.14 CD5AA 048 1.00 1.04
CK3BA 048 1.00 1.13 CD5AB 048 1.00 1.04
060 1.00 1.12 CE3AA 048 1.00 1.04
CK5A/CK5BA 048 1.00 1.13 060 1.00 1.03
060 1.00 1.12 CK3BA 048 1.00 1.03
CK5A/CK5BN 048 1.00 1.13 060 1.00 1.02
060 1.00 1.12 CK5A/CK5BA 048 1.00 1.03
CK5A/CK5BT 048 1.00 1.13 060 1.00 1.01
060 1.00 1.12 CK5A/CK5BN 060 1.00 1.03
CK5A/CK5BW 048 1.00 1.13 CK5A/CK5BT 048 1.00 1.03
CK5A/CK5BX 060 1.00 1.12 060 1.00 1.01
FK4CNB 006 1.00 1.00 CK5A/CK5BW 048 1.00 1.03
FK4CNF 005 1.00 1.00 CK5A/CK5BX 060 1.00 1.02
FV4ANB 006 1.00 1.01
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
FV4ANF 005 1.00 1.00 CC5A/CD5AA 060 1.00 1.05
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
CC5A/CD5AB 060 1.00 1.05
CC5A/CD5AA 060 1.00 1.06 CC5A/CD5AC 048 1.00 1.07
CC5A/CD5AB 060 1.00 1.06 CC5A/CD5AW 048 1.00 1.04
CC5A/CD5AC 048 1.00 1.08 060 1.00 1.03
CC5A/CD5AW 048 1.00 1.05 CD5AA 048 1.00 1.05
060 1.00 1.04 CD5AB 048 1.00 1.05
CD5AA 048 1.00 1.05 CE3AA 048 1.00 1.05
CD5AB 048 1.00 1.05 060 1.00 1.04
CE3AA 048 1.00 1.05 CK3BA 048 1.00 1.04
060 1.00 1.05 060 1.00 1.02
CK3BA 048 1.00 1.05 CK5A/CK5BA 048 1.00 1.04
060 1.00 1.03 060 1.00 1.02
CK5A/CK5BA 048 1.00 1.05 CK5A/CK5BN 060 1.00 1.03
060 1.00 1.03 CK5A/CK5BT 048 1.00 1.04
CK5A/CK5BN 048 1.00 1.05 060 1.00 1.02
060 1.00 1.04 CK5A/CK5BW 048 1.00 1.04
CK5A/CK5BT 048 1.00 1.05 CK5A/CK5BX 060 1.00 1.03
060 1.00 1.03 ——