Bryant 698B Heat Pump User Manual


 
28
HEAT PUMP HEATING PERFORMANCE
See notes on page 41.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
3 7 17 27 37 47 57 67
EDB CFM
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Capacity
MBtuh
Total
Pwr
Total Int* KWTotal Int* KWTotal Int* KWTotal Int* KWTotal Int* KWTotal Int* KWTotal Int* KWTotal Int* KW
698BNX024000 Outdoor Section With FV4ANF002000 Indoor Section - High Speed
65
600 6.16 5.67 1.11 8.70 8.00 1.23 11.39 10.38 1.35 14.28 12.68 1.48 17.55 15.97 1.63 21.03 21.03 1.79 25.05 25.05 1.98 29.71 29.71 2.20
700 6.41 5.90 1.13 8.98 8.26 1.25 11.68 10.65 1.35 14.74 13.09 1.49 18.04 16.42 1.62 21.57 21.57 1.78 25.69 25.69 1.98 29.98 29.98 2.13
800 6.57 6.04 1.14 9.19 8.45 1.26 11.95 10.89 1.36 15.05 13.37 1.49 18.37 16.72 1.62 21.92 21.92 1.78 26.13 26.13 1.95 29.19 29.19 2.07
900 6.71 6.17 1.16 9.36 8.60 1.27 12.16 11.09 1.37 15.30 13.59 1.50 18.58 16.91 1.63 22.14 22.14 1.79 26.04 26.04 1.93 28.38 28.38 2.03
70
600 5.62 5.17 1.12 8.16 7.50 1.25 10.81 9.85 1.37 13.65 12.12 1.51 16.87 15.35 1.66 20.31 20.31 1.82 24.26 24.26 2.02 28.81 28.81 2.25
700 5.79 5.33 1.13 8.41 7.73 1.26 11.11 10.13 1.38 14.05 12.48 1.51 17.38 15.81 1.65 20.88 20.88 1.82 24.86 24.86 2.01 29.50 29.50 2.19
800 5.94 5.46 1.15 8.62 7.92 1.27 11.38 10.37 1.39 14.36 12.76 1.51 17.72 16.13 1.66 21.23 21.23 1.82 25.33 25.33 2.02 29.04 29.04 2.13
900 6.07 5.59 1.16 8.85 8.13 1.29 11.60 10.57 1.40 14.63 12.99 1.52 17.98 16.36 1.66 21.46 21.46 1.82 25.59 25.59 1.98 28.41 28.41 2.10
75
600 4.97 4.58 1.12 7.55 6.94 1.26 10.23 9.33 1.39 12.99 11.54 1.53 16.15 14.70 1.68 19.59 19.59 1.86 23.45 23.45 2.05 27.91 27.91 2.29
700 5.14 4.73 1.13 7.74 7.11 1.27 10.53 9.60 1.40 13.41 11.91 1.53 16.69 15.19 1.68 20.14 20.14 1.85 24.10 24.10 2.04 28.75 28.75 2.25
800 5.29 4.87 1.15 8.00 7.35 1.28 10.78 9.83 1.41 13.73 12.20 1.54 17.06 15.52 1.69 20.53 20.53 1.85 24.54 24.54 2.05 28.80 28.80 2.20
900 5.43 4.99 1.16 8.16 7.50 1.30 10.98 10.01 1.42 13.96 12.40 1.54 17.33 15.77 1.69 20.78 20.78 1.86 24.88 24.88 2.04 28.30 28.30 2.17
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 024 0.97 1.12 FV4ANF 002 1.00 1.00
030 0.96 1.13 003 0.98 1.00
036 1.00 1.11
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
CC5A/CD5AB 024 0.97 1.12 CC5A/CD5AA 024 0.94 1.04
030 0.96 1.12 030 0.93 1.04
036 1.00 1.11 036 0.98 1.02
CC5A/CD5AW 024 0.97 1.12 CC5A/CD5AB 024 0.94 1.04
030 0.96 1.13 030 0.93 1.04
036 1.00 1.11 036 0.98 1.02
CE3AA 024 0.98 1.11 CC5A/CD5AW 024 0.94 1.03
030 1.00 1.10 030 0.93 1.04
036 0.99 1.11 036 0.98 1.02
CF5AA 024 0.98 1.11 CE3AA 024 0.95 1.03
036 1.00 1.12 030 0.97 1.02
CK3BA 024 1.01 1.09 036 0.96 1.02
030 0.98 1.12 CK3BA 024 0.99 1.00
036 1.00 1.10 030 0.95 1.02
CK5A/CK5BA 024 1.01 1.09 036 0.98 1.01
030 0.98 1.11 CK5A/CK5BA 024 0.98 1.03
036 1.01 1.10 030 0.98 1.02
CK5A/CK5BN 036 1.01 1.10 036 0.98 1.01
CK5A/CK5BT 036 1.01 1.10 CK5A/CK5BN 036 0.98 1.02
CK5A/CK5BW 024 1.01 1.09 CK5A/CK5BT 036 0.98 1.01
030 0.98 1.11 CK5A/CK5BW 024 0.98 1.02
036 1.01 1.10 030 0.98 1.02
FK4CNF 001 0.98 1.02 ——
002 1.00 1.00
003 0.98 1.00