Bryant 698B Heat Pump User Manual


 
2
DIMENSIONS
A01063
DIMENSIONS (IN.)
SOUND POWER (dBA)
*Sound levels are equivalent at high and low speeds.
UNIT
SIZE SERIES A B C D E F G H K L M N
MINIMUM MOUNTING
PAD DIMENSIONS
024 A 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 5/8 12 13-3/4 12 2-3/8 20 x 27
036 A 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 3/4 16-1/4 14 13-1/8 2-15/16 26 x 32
048 A 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/4 14-1/4 14-1/2 2-15/16 26 x 32
060 A 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16 13-3/4 15-3/4 2-15/16 26 x 32
UNIT
SIZE
SOUND
LEVEL*
OCTAVE BAND CENTER FREQUENCY (Hz)
125 250 500 1000 2,000 4,000 8,000
High Speed
024 74 52.9 58.4 58.8 68.5 57.7 53.0 45.4
036 74 53.9 59.4 60.8 65.5 58.7 53.5 48.4
048 75 53.9 59.9 59.8 63.0 60.7 53.5 48.9
060 76 52.4 58.4 58.8 62.0 63.2 58.0 52.4
AIR DISCHARGE
AIR DISCHARGE
AIR IN
AIR IN
AIR IN
3
/8"
DIA. TIEDOWN KNOCKOUTS
(2) PLACES
L
K
N
E
D
C
L
ACCESS
PANEL
1
1
/4
"
2
1
/2
"
AIR DISCHARGE
1
3
/4
"
4
3
/16
"
3
/8"
DIA. LIQUID
LINE CONN.
H
DIA. VAPOR
LINE CONN.
7
/8"
DIA. HOLE
FIELD POWER SUPPLY CONN.
7
/8"
DIA.
HOLE WITH 1
1
/8"
DIA. KNOCKOUT
AND 1
3
/8"
DIA. KNOCKOUT
10
1
/2
"
FIELD CONTROL
SUPPLY CONN
1
9
/16
"
C
F
8
3
/16
"
G
A
B
M
NOTES:
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55°F,
(UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125°F.
3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66°F.
4. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER.
5. CENTER OF GRAVITY .