FACTORY OPTIONS AND/OR ACCESSORIES
Economizer (dry--bulb or enthalpy)
Economizers save money. They bring in fresh, outside air
for ventilation; and provide cool, outside air to cool your
building. This is the preferred method of low--ambient
cooling. When coupled to CO
2
sensors, Economizers can
provide even more savings by coupling the ventilation air
to only that amount required.
Economizers are available, installed and tested by the
factory, with either enthalpy or dry--bulb temperature
inputs. There are also m odels for electromechanical as
well as direct digital controllers. Additional sensors are
available as accessories to optimize the economizers.
CO
2
Sensor
Improves productivity and saves money by working with
the economizer to intake only the correct amount of
outside air for ventilation. As occupants fill your building,
the CO
2
sensor detects their presence through increasing
CO
2
leve ls, and opens the economizer appropriately.
When the occupants leave, the CO
2
levels decrease, and
the sensor appropriatel y closes the economizer. This
intelligent control of the ventilation air , called Demand
Control Ventilation (DCV) reduces the overall load on the
rooftop, savi ng money.
Smoke Detectors
Trust the experts. Smoke detectors make your application
safer a nd your job easier. Bryant’s smoke detectors
immediately shut down the rooftop unit when smoke is
detected. They are available, installed by the factory, for
supply air, return air, or both.
Louvered Hail Guards
Sleek, louvered panels protect the condenser coil from
hail damage, foreign objects, and incidental contact.
Convenience Outlet (powered or u n--powered)
Lower service bills by including a convenience outlet in
your specification. Bryant will install this servi ce feature
at our factory, powered. Provides a convenient, 15 amp,
115v GFCI receptacle.
Non--fused Disconnect
This OSHA-- compliant, factory--installed, safety switch
allows a service technician to locally secure power to the
rooftop.
Barometric Relief
Gravity controlled, barometric relief equalizes building
pressure and ambient air pressures. This can be a cast
effective solution to prevent building pressurization.
Power Exhaust with Barometric Relief.
Superior internal building pressure control. This
field--installed accessory may eliminate the need for
costly, external pressure control fans.
RTU--MP, Multi--protocol Controller
Connect the rooftop to an existing BAS without needing
complicated translators or adapter modules using the
RTU--MP controller. This new control ler speaks the 4
most common building automation system languages
(Bacne t, Modbus, N2, and Lonworks). Use this cont roller
when you have an e xisting BAS.
Time Guard II Control Circuit
This accessory protects your compressor by preventing
short--cycling in the event of some other failure, prevents
the compressor from restarting for 30 seconds after
stopping. Not required with PC, RTU--MP, or authorized
commercial thermostats.
Filter or Fan Status Switches
Use these differential pressure switches to detect a filter
clog or indoor fan motor fai lure. When used in
conjunction with a compatible unit controller/thermostat,
the switches will activate an alarm to warn the appropriate
personnel.
Motorized 2--Position Damper
Bryant’s new, 2--position, motorized outdoor air damper
admits up to 100% outside air. Using reliable, gear-- driven
technology, t he 2--position damper opens to allow
ventilation air and closes when the rooftop stops, stopping
unwanted infiltration.
Manual OA Damper
Manual outdoor ai r dampers are an economi cal way to
bring in ventilation air.
Motormaster Head Pressure Controller
The Motormaster motor controller is a low ambient, head
pressure controller kit that is designed to maintain the
unit’s condenser head pressure during periods of low
ambient cooling operation. This device should be used as
an alternative to economizer free cooling not when
economizer usage is either not appropria te or desired. The
Motormaster will either cycle the outdoor--fan motors or
operate them at reduced speed to maintain the unit
operat ion, depending on the model.
Winter Start Kit
Bryant’s winter start kit extends the low ambient limit of
your rooftop to 25_F(--9_C). The kit bypasses the low
pressure switch, preventing nuisance tripping of the low
pressure switch. Other low ambient precautions may still
be prudent.
UV--C Lights
Bryant’s commercial rooftop ultra--violet germicidal
lamps are de signed to kill odor causing mold and fungus
that may develop in the cool and damp evaporator section
of an HVAC unit. The high output, low temperature
germicidal lamps are installed in the evaporator section of
the HVAC unit, and shine directly on the evaporator coil
558J