Bryant 558J Fan User Manual


 
3
FEATURES AND BENEFITS
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S 3 --6 ton units fit on existing Bryant small rooftop curb. This saves time and money on replacement jobs.
S Standardized components and layout. Standardized components and controls make service and stocki ng parts easier.
S Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble --shooting easier.
S Field convertible airflow (3--6 tons). Being able to c onvert a uni t from vertical airflow to horizontal makes it easy to
overcome job site complications.
S Easy--adjust, belt--drive motor available. Bryant provides a fac tory solution for most points in the fan performanc e table.
There ’s no need for field--supplied drives or motors.
S Provisions for bottom or side condensate drain.
S Capable of thru--the--base or thru--the--curb electrical routing.
S Single--point electrica l connection.
S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.
S Standardized controls and control box layout. Standardized components and controls make stocking parts and service
easier.
S Clean, easy to use control box.
S Color--coded wiring.
S Large, laminated wiring and power drawings which are affixed to unit make troubleshooting easy.
S Single, central terminal board for test and wiring connections.
S Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
S “No--strip” screw system guides screws i nto the panel and captures them tightly without stripping the screw, the panel, or
the unit.
S Exclusive, newly--design indoor refrigerant header for easier maintenance and replacement.
S Mechanical cooling (115_F--25_F/46_C--4_C) on Direct Digita l Controller (DDC) (RTU--MP controller).
S Mechanical cooling (115_F--25_F/46_C--4_C) on Electro--Mechanical (E/M) models, with winter start kit.
S Bryant’s naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically,
manua lly drained. This saves labor and maintenance expense.
S 2” throw away filters on all units.
S Refrigerant filter-- drier.
S High and low pressure switches. Added reliability with high pressure switch and low pressure switch.
the environmentally sound refrigerant
Thisproducthasbeen designedandmanufacturedto
meetEnergyStar®criteriaforenergyefficiency.
However,proper refrigerantchargeandproperair flow
arecriticaltoachieveratedcapacityandefficiency.
Installationofthisproductshouldfollowall
manufacturer’srefrigerantchargingandairflow
instructions.Failuretoconfirmproperchargeand
airflowmayreduceenergyefficiencyandshorten
equipmentli f e.
558J