Bryant 223A Heat Pump User Manual


 
56
HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOOR AIR
OUTDOORCOILENTERING AIRTEMPERATURES°F (°C)
---3 ( ---19.4) 7 (---13.9) 17 (---8.3) 27(---2.8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB CFM
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ*
223A*A060---B Outdoor Section With FY4ANF060 Indoor Section
65
(18.3)
1750 25.07 23.07 3.86 30.90 28.40 4.00 37.17 33.89 4.16 43.81 38.91 4.34 51.11 46.51 4.54 59.85 59.85 4.79 68.95 68.95 5.02 78.00 78.00 5.31
2000 25.62 23.57 3.93 31.49 28.94 4.06 37.79 34.45 4.20 44.47 39.50 4.36 51.96 47.28 4.54 60.88 60.88 4.74 69.47 69.47 4.95 78.33 78.33 5.20
2250 26.13 24.04 4.01 32.03 29.44 4.13 38.34 34.96 4.26 45.07 40.03 4.40 52.72 47.97 4.57 61.49 61.49 4.73 69.75 69.75 4.92 77.76 77.76 5.13
70
(21.1)
1750 24.34 22.40 4.03 30.22 27.77 4.19 36.54 33.32 4.36 43.21 38.37 4.55 50.41 45.87 4.76 58.98 58.98 5.03 68.13 68.13 5.26 77.06 77.06 5.56
2000 24.89 22.90 4.10 30.80 28.30 4.24 37.17 33.89 4.40 43.87 38.96 4.57 51.17 46.57 4.75 60.00 60.00 4.97 68.71 68.71 5.18 77.50 77.50 5.44
2250 25.40 23.37 4.18 31.34 28.80 4.31 37.72 34.39 4.45 44.46 39.49 4.60 51.85 47.19 4.77 60.72 60.72 4.95 69.06 69.06 5.15 77.77 77.77 5.39
75
(23.9)
1750 23.57 21.68 4.21 29.50 27.11 4.38 35.86 32.70 4.57 42.56 37.80 4.77 49.72 45.25 4.99 57.81 57.81 5.26 67.28 67.28 5.51 76.15 76.15 5.82
2000 24.12 22.19 4.29 30.09 27.65 4.44 36.50 33.28 4.60 43.24 38.40 4.78 50.48 45.93 4.98 58.94 58.94 5.21 67.93 67.93 5.43 76.69 76.69 5.70
2250 24.63 22.66 4.37 30.63 28.15 4.51 37.07 33.80 4.66 43.83 38.93 4.82 51.15 46.54 5.00 59.80 59.80 5.19 68.35 68.35 5.40 76.95 76.95 5.64
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
*FY4ANB060 1.00 1.00
FE4ANB006 0.98 0.95
FV4BNB006 0.98 0.94
FX4CN(B,F)060 0.98 0.94
CAP**6021A** 0.97 1.00
CAP**6024A** 0.98 0.99
CNPH*6024A** 0.98 0.99
CNPV*6024A** 0.98 0.99
CSPH*6012A** 0.98 0.98
CAP**6021A** 0.94 0.98 315(A,J)AV060110
CNPH*6024A** 0.96 1.00 315(A,J)AV060110
CSPH*6012A** 0.96 0.98 315(A,J)AV060110
CAP**6024A** 0.96 0.99 315(A,J)AV066135
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.95 0.99 315(A,J)AV066135
CNPV*6024A** 0.95 0.99 315(A,J)AV066135
CSPH*6012A** 0.96 0.98 315(A,J)AV066135
CAP**6024A** 0.96 0.98 315(A,J)AV066155
CNPH*6024A** 0.95 0.98 315(A,J)AV066155
CNPV*6024A** 0.95 0.98 315(A,J)AV066155
CSPH*6012A** 0.96 0.97 315(A,J)AV066155
CNPH*6024A** 0.97 1.02 353AAV048080
CSPH*6012A** 0.98 1.01 353AAV048080
CAP**6021A** 0.97 0.99 353AAV060100
CNPH*6024A** 0.97 1.00 353AAV060100
CSPH*6012A** 0.97 0.98 353AAV060100
CAP**6024A** 0.97 0.99 353AAV060120
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.97 0.99 353AAV060120
CNPV*6024A** 0.97 0.99 353AAV060120
CSPH*6012A** 0.97 0.98 353AAV060120
CAP**6021A** 0.97 1.00 313*AV048090
CNPH*6024A** 0.97 1.01 313*AV048090
CSPH*6012A** 0.97 0.99 313*AV048090
CAP**6021A** 0.98 0.99 313*AV060110
CNPH*6024A** 0.97 0.99 313*AV060110
CSPH*6012A** 0.97 0.97 313*AV060110
CAP**6024A** 0.97 1.00 313*AV060135
CNPH*6024A** 0.97 1.00 313*AV060135
CNPV*6024A** 0.97 1.00 313*AV060135
CSPH*6012A** 0.97 0.98 313*AV060135
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
EDB —EnteringDryBulb
223A