Bryant 223A Heat Pump User Manual


 
47
HEAT PUMP HEATING PERFORMANCE
INDOOR AIR
OUTDOORCOILENTERING AIRTEMPERATURES°F (°C)
---3 ( ---19.4) 7 (---13.9) 17 (---8.3) 27(---2.8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB CFM
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Capacity MBtuh
Total
Sys.
KW†
Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ*
223A*A018---C Outdoor Section With FY4ANF018 Indoor Section
65
(18.3)
525 6.61 6.08 0.80 8.47 7.79 0.84 10.49 9.56 0.87 12.71 11.29 0.91 15.25 13.88 0.96 18.01 18.01 1.02 21.07 21.07 1.09 23.90 23.90 1.15
600 6.77 6.23 0.81 8.66 7.96 0.84 10.69 9.75 0.87 12.97 11.52 0.91 15.55 14.15 0.95 18.36 18.36 1.01 21.41 21.41 1.06 24.06 24.06 1.12
675 6.92 6.37 0.82 8.82 8.11 0.85 10.87 9.91 0.88 13.19 11.71 0.91 15.80 14.38 0.95 18.65 18.65 1.00 21.54 21.54 1.05 24.09 24.09 1.10
70
(21.1)
525 6.29 5.79 0.83 8.20 7.53 0.87 10.20 9.30 0.91 12.39 11.01 0.95 14.87 13.53 1.00 17.64 17.64 1.06 20.64 20.64 1.14 23.62 23.62 1.20
600 6.46 5.94 0.84 8.39 7.71 0.88 10.41 9.49 0.91 12.62 11.21 0.95 15.21 13.84 0.99 18.00 18.00 1.05 21.06 21.06 1.11 23.79 23.79 1.17
675 6.61 6.08 0.86 8.53 7.84 0.89 10.59 9.66 0.92 12.87 11.43 0.95 15.46 14.07 0.99 18.28 18.28 1.04 21.29 21.29 1.10 23.87 23.87 1.15
75
(23.9)
525 5.96 5.48 0.86 7.87 7.23 0.90 9.91 9.03 0.95 12.09 10.74 0.99 14.52 13.21 1.04 17.27 17.27 1.11 20.23 20.23 1.19 23.29 23.29 1.26
600 6.12 5.63 0.87 8.06 7.40 0.91 10.12 9.22 0.95 12.33 10.95 0.99 14.82 13.49 1.04 17.62 17.62 1.10 20.67 20.67 1.17 23.50 23.50 1.22
675 6.27 5.77 0.89 8.24 7.58 0.92 10.30 9.39 0.95 12.54 11.14 0.99 15.07 13.71 1.03 17.90 17.90 1.09 20.94 20.94 1.15 23.61 23.61 1.20
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
*FY4ANF018 1.00 1.00
FE4ANF002 0.93 0.87
FF1ENP018 1.00 1.00
FF1ENP024 0.98 0.97
FV4BNF002 0.93 0.87
FX4CNF018 0.98 0.92
FX4CNF024 0.96 0.89
FY4ANF024 1.00 0.99
CAP**1814A** 1.00 1.01
CAP**2414A** 1.00 0.97
CAP**2417A** 1.00 0.97
CNPF*2418A** 1.00 0.96
CNPH*2417A** 1.00 0.96
CNPV*1814A** 1.00 0.97
CNPV*2414A** 1.00 0.96
CNPV*2417A** 1.00 0.96
CSPH*2412A** 1.00 0.95
CAP**1814A** 0.95 0.95 315(A,J)AV036070
CAP**2414A** 0.96 0.93 315(A,J)AV036070
CNPH*2417A** 0.97 0.92 315(A,J)AV036070
CNPV*1814A** 0.97 0.94 315(A,J)AV036070
CNPV*2414A** 0.97 0.92 315(A,J)AV036070
CSPH*2412A** 0.97 0.92 315(A,J)AV036070
CAP**2417A** 0.97 0.92 315(A,J)AV048090
CNPH*2417A** 0.97 0.92 315(A,J)AV048090
CNPV*2417A** 0.97 0.92 315(A,J)AV048090
CSPH*2412A** 0.97 0.92 315(A,J)AV048090
CAP**2417A** 0.99 0.88 353AAV036040
CNPH*2417A** 0.99 0.88 353AAV036040
CNPV*2417A** 0.99 0.88 353AAV036040
CSPH*2412A** 0.98 0.89 353AAV036040
CAP**2417A** 0.98 0.89 353AAV036060
CNPH*2417A** 0.98 0.90 353AAV036060
CNPV*2417A** 0.98 0.90 353AAV036060
CSPH*2412A** 0.97 0.91 353AAV036060
CNPH*2417A** 0.97 0.92 355(A,C)AV042040
CSPH*2412A** 0.97 0.92 355(A,C)AV042040
CAP**2417A** 0.97 0.93 355(A,C)AV042060
CNPH*2417A** 0.97 0.92 355(A,C)AV042060
CNPV*2417A** 0.97 0.92 355(A,C)AV042060
HEATING INDOOR
MODEL
CAPACITY POWER FURNACE MODEL
CSPH*2412A** 0.97 0.92 355(A,C)AV042060
CNPH*2417A** 0.97 0.92 355(A,C)AV042080
CSPH*2412A** 0.97 0.92 355(A,C)AV042080
CAP**1814A** 0.97 0.94 313*AV024045
CAP**2414A** 0.98 0.91 313*AV024045
CNPH*2417A** 0.98 0.91 313*AV024045
CNPV*1814A** 0.98 0.93 313*AV024045
CNPV*2414A** 0.98 0.91 313*AV024045
CSPH*2412A** 0.98 0.91 313*AV024045
Seenoteonpg.56
223A