Bradley Smoker SS-2/IR/JUV Plumbing Product User Manual


 
5
Express® Lavatory System SS-Series
Installation Instructions - For Service Only SS-2/IR/STD, SS-2/IR/JUV
Bradley Corporation • 215-1243 Rev. D; EN 03-813 5/11/04
Installation Instructions
Step 1: Rough in
Note: See Figure 1a below (for Standard Height) and Figure 1b on page 6 (for Juvenile Height)
when roughing in the Express®.
IMPORTANT: Flush the supply lines before making connections. Debris in supply
lines will cause the valves to malfunction.
IMPORTANT: Dimensions shown in Figure 1a are for a Standard Height
Express® only.
1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.
2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.
(MM)
32"
(813)
28-5/8"
(727)
25"
(635)
11-3/8"
(289)
19-5/8"
(498)
(6) 3/8" WALL ANCHORS
WITH MINIMUM PULL-
OUT RATING OF 1,000
LBS.
23-1/2"
(597)
9-3/8"
(238)
2-3/4"
(70)
13-1/2"
(343)
1" (25)
23-1/2"
(597)
9-3/8"
(238)
3"
(76)
1/2" NPT HOT AND
COLD SUPPLIES,
OR TEMPERED
SUPPLY - STUB
OUT 2" (50) FROM
WALL
FINISHED
FLOOR
CENTERLINE
15-1/4"
(387)
1-1/2" NPT DRAIN -
STUB OUT 2" (50)
FROM WALL
110 Volt GFCI
ELECTRICAL
OUTLET
Figure 1a
Installation Instructions
continue . . .
SS-2/IR/STD Express® Lavatory System Dimensions
Standard Height Mounting