Bradley Smoker SS-2/IR/JUV Plumbing Product User Manual


 
2
Express® Lavatory System SS-Series
SS-2/IR/STD, SS-2/IR/JUV Installation Instructions - For Service Only
5/11/04 Bradley Corporation • 215-1243 Rev. D; EN 03-813
Pre-Installation Information
Barrier-free and ADA compliant - standard height mounting
The SS-2/IR/STD Express® Lavatory System must have a rim height of 34" above finished
floor to be compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim
height, the Express® meets ADA, ANSI and UFAS requirements for barrier-free clearances,
reaches and controls. Always check local codes and ordinances for compliance.
Barrier-free and ADA compliant - juvenile height mounting
The SS-2/IR/JUV Express® Lavatory System is compliant with Americans with Disabilities Act
(ADA) Accessibility Guidelines for Buildings and Facilities: Building Elements Designed for
Children's Use; Final Rule.
Infrared sensor and solenoid
Each sprayhead is controlled by a separate sensor and solenoid valve, enabling each user to activate
a single flow of water. Each valve uses less than half the maximum of hot water allowed by the
ANSI/ASHRAE/IES 90A-1980 Standard.
Supplies required for installation:
(6) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall
(minimum pull-out rating of 1,000 lbs.)
1/2" NPT hot and cold supply piping
1-1/2" NPT drain piping
110 volt electrical outlet for 110/24 VAC plug-in transformer
(supplied)