Bradford-White Corp TG-150I-N(X) Water Heater User Manual


 
28
Vertical Direct Vent Installations
The EverHot
TG series water heaters can also be installed to vent vertically through the roof using a
vertical discharge adapter, optional vent extension tubes, the condensate collector, a roof terminal, and a
universal lead tile. Use of the condensate collector is required on all vertical venting heights over 5 feet
(1.5 m). Determine the distance in height required from the water heater and order the vent extension
pipes required.
Figure 12. Vertical Vent Installations.
The condensate collector will require a pipe connection with a trap to act as a seal against discharging
flue products into the room. Run the condensate line to a suitable drain.
CAUTION
A trap must be installed after the condensate collector to prevent flue products from leaking into the
room.