Prior to the Installation of the EverHot
Direct Vent System
The EverHot TG series water heaters have two adjustable wall mounting support brackets fitted on the
top and bottom of the water heater casing. When installing a “Standard Vent Discharge Kit” to vent
directly out the wall to the back of the water heater, these brackets should be adjusted so that the water
heater is moved out the maximum 2” (5.1 cm) away from the wall. Before cutting the vent terminal to the
required length, ensure that the distance the water heater is away from the wall has been accounted for.
Horizontal Direct Vent Installations
Whenever possible, install the EverHot TG series water heater on or near an outside wall for the shortest
vent with the least number of elbows. The standard vent kit available for this water heater consists of one
90 vent discharge adapter and a horizontal vent termination kit. This kit is for venting directly through an
outside wall.
Figure 9. Standard Vent Kit – Horizontal Direct Vent Installations
(Excludes TG-237I-N(X) and TG-237I-N(X)A models).
For installations on interior walls, venting components may be purchased from the venting suppliers listed
in this manual to extend the venting distance using extension tubes and elbows. Use the formula and
venting table shown previously in this manual to calculate the total equivalent distance of vent pipe. Do
not exceed the maximum of 41 equivalent feet (12.5 m). If the height of the vent pipe is extended 5 feet
(1.5 m) or more above the top of the water heater, the condensate collector must be used. Refer to the
parts list at the end of this manual, as well as the Venting System Installation Instructions supplied with
the venting for available venting components and detailed instructions on fitting the components together.