Bosch Appliances LTC 8016/90 Home Security System User Manual


 
EN
|
16
Bosch Security Systems | 18 August 2005
LTC 8016/90 | Instruction Manual | Installation
LTC 8016 Interface Unit
PC
INPUTS
15
16
13
14
11
12
9
10
8
6
5
3
4
2
LOOPING VIDEO 1-16
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
7
1
RS-232
RS-485 IN
RS-485 OUT
DATA
ETHERNET
10/100 BaseT
ACTLINK
CODE
BIPHASE IN
GROUP ID
0
2
6
4
8
0
2
6
4
8
0
2
6
4
8
LTC 5136 Series Controller
LTC 5136
Data
Converter
Unit
Power
Supply
Adaptor
RS-232
Data &
Power
Biphase Control
Code Output
Figure 10 Biphase Data Interface Connection Detail
LTC 8016 Interface Unit
PC
INPUTS
15
16
13
14
11
12
9
10
8
6
5
3
4
2
LOOPING VIDEO 1-16
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
7
1
RS-232
RS-485 IN
RS-485 OUT
DATA
ETHERNET
10/100 BaseT
ACTLINK
CODE
BIPHASE IN
GROUP ID
0
2
6
4
8
0
2
6
4
8
0
2
6
4
8
Typical PC-based DVR Unit
Biphase RS-232
Code Output Data
User-supplied Cable (see text)
Figure 11 Biphase RS-232 Data Interface Connection Detail
To connect the Interface Unit to a biphase controller,
attach the biphase data cable from the controller to the
biphase input terminal block on the rear panel of the
Interface Unit. Use the straight slot end of the supplied
offset screwdriver to tighten the terminal block screws.
The Interface Unit supports daisychain biphase
connections to simplify connection to multiple
Interface Units. If this type of connection is necessary,
remove the termination resistor from the biphase
output terminal block, and connect another user-
supplied shielded twisted pair cable from the output of
one Interface Unit to the input of another.
4.8 Data Connections Using Biphase
RS-232 Protocol
The Interface Unit can be connected directly to Bosch
Security System products that generate biphase control
data in RS-232 format. These products include the
PC-based DiBos, and DESA Series Digital Video
Recorders.
Typically, the RS-232 interface of the controller first
connects to an optional LTC 8786 or LTC 8780 Data
Converter accessory unit. The outputs from the Data
Converter Unit can be connected to P/T/Z cameras or
other devices designed to receive standard biphase
code protocol.
Although the LTC 8016 is capable of receiving
standard biphase protocol, it can also directly accept
biphase in an RS-232 format. Any controller capable
of generating biphase data in an RS-232 format
operating at 9600, 19200, 57600, or 115200 baud,
with 8 data bits, no parity, and 1 stop bit, can be
connected to the Interface Unit.
When RS-232 communication is first established,
the Interface Unit may require 3 to 5 seconds to
automatically detect and adjust to the controller’s
baud rate. No control of cameras is possible until
this process is completed.
Refer to the portion of the next section that is
applicable to your configuration, based on the
controller product being connected to the
Interface Unit.