Bosch Appliances D9412GV3 Home Security System User Manual


 
D9412GV3/D7412GV3 | Operation and Installation Guide | 13.0 Programmer and Accessory Connections
.
Bosch Security Systems, Inc. | 10/10 | F01U143070-03 62
13.0 Programmer and
Accessory Connections
13.1 Programmer Connector
Control panel firmware version 8.11 and later does
not support the D5200 Programmer. Instead, a limited
local keypad programming mode is available. Refer to
Section 13.2 Installer Keypad and Local Programmers
Mode on page 62 for details.
Figure 31: Reset Pin
1 - Reset Pin locked (closed)
2 - Reset Pin normal (open) for normal control
panel operation
When the Reset Switch (labeled S1)
is closed, the communication module
at SDI Address 92 is disabled. While
in this mode, remote programming
communication is only supported by
the communication module at SDI
Address 88.
13.2 Installer Keypad and Local
Programmers Mode
While installing or maintaining a D9412GV3 or
D7412GV3 control panel, it is sometimes necessary
to change the configuration. To do so, a local keypad
programming menu is available in the Service Menu.
You can access the Service Menu when the control
panel is in stand-by mode or while it is operating.
Refer to the D9412GV3/D7412GV3 Control Panel
Program Entry Guide (P/N: F01U170807) for an
explanation of the programming menu.
Accessing Local Keypad Programming when the
Control Panel is Operating (Reset Switch Open)
To access the Local Programmers Menu while the
control panel is operating:
1. Disarm all areas in the control panel.
Local keypad programming is only accessible
when all areas are disarmed.
2. At any D1255 or D1260 Keypad, press
[9][9][ENTER] to access the Service Menu.
3. Enter the Service passcode when prompted.
4. Advance the menu to the Keypad Programming
option, then press [ENTER] to enter programming
mode.
The Keypad Programming menu is only available
when all areas in the control panel are disarmed.
Accessing Local Keypad Programming when the
Control Panel is in Standby Mode (Reset Switch
Closed)
The control panel is in standby mode when the Reset
pin is closed. Refer to Figure 31. While the control
panel is in standby mode, you can access the Service
Menu at one of two keypads with the following
restrictions:
An unsupervised D1260 Keypad (all versions)
at SDI Bus Address 8.
The D1260 Keypad does not support SDI Bus
Address 16.
An unsupervised D1255 Keypad (all versions)
at SDI Bus Address 16.
If a D1255 is set to SDI Bus Address 8, then
that keypad cannot be used to access the
Service Menu.
Only one keypad at a time is allowed to be in
use.
To access Local Keypad Programming when the
control panel is in standby mode:
1. From the keypad (D1260 at SDI Address 8 or
D1255 ad SDI Address 16), enter the Service
Passcode.
2. Advance the menu to the Keypad Programming
option.
3. Press [ENTER] to enter Local Keypad
Programming.
13.3 Programmer Access Reports
When a program is sent to the control panel from
RPS, the control panel sends a Prog Access OK
report 10 sec after the reset switch is unlocked, or
when the programmer disconnects. The prompt in
routing must be programmed Yes to send this report.