Bosch Appliances CC408 Home Security System User Manual


 
CC408 | Operators Guide | 5. Arming the System EN | 8
Bosch Security Systems | 5/04 | 920050O.OG.112
Forced Arming
The feature of arming the system when a zone is not
sealed is known as forced arming. If the system does
not arm and a long beep is heard, forced arming is
not permitted. If this is the case, ensure that all zones
are sealed or manually isolated before arming the
system.
5.1 Arming in AWAY Mode
When you leave your premises and require all zones
to be in a ready state to detect intrusion, you arm the
system in AWAY Mode. When returning to your
premises, disarm your system (see Section 6. Disarming
the System) so you do not sound a false alarm.
There are two different methods for arming the
system in AWAY Mode. Method one is standard and
always operates. Method two is optional and may be
disabled by your installer if you do not want to use
single button arming.
Arming in AWAY Mode, Method 1
Enter your user code followed by the [#] key (for
example, [2 5 8 0 #]). Two beeps sound and the
AWAY indicator displays. Exit time starts counting.
Arming in AWAY Mode, Method 2
Hold down the [#] key until two beeps sound.
The AWAY indicator displays and exit time starts
counting.
5.2 Arming in STAY Mode 1
STAY Mode 1 is only used when the perimeter and
unused areas of the premises must be armed to
detect if an intruder is entering the premises. At the
same time it allows you to move freely within an area
that is automatically isolated.
Only your security company can program
zones automatically isolated in STAY
Mode 1.
There are two different methods for arming the
system in STAY Mode 1. Method one is standard
and always operates. Method two is optional and
may be disabled by your installer if you do not want
to use single button arming.
Entry Guard Timer for STAY Mode 1
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer For
STAY Mode 1 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and triggers an alarm condition. Entry Guard Timer
For STAY Mode 1 is the delay time used for all
zones except 24-hour zones when the system is
armed in STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode 1 is
programmed and a zone not automatically isolated is
triggered, the codepad beeps twice per second until
the entry timer expires or the system disarms. If the
alarm condition is not reset by entering your user
code followed by the [#] key (for example,
[2 5 8 0 #]) before the entry timer expires, the sirens
activate into alarm. Only your installer can program
this feature.
Arming in STAY Mode 1, Method 1
Enter your user code followed by the [*] key (for
example, [2 5 8 0 *]). Two beeps sound and the
STAY indicator displays. Exit time starts counting.
Any zones programmed to be automatically isolated
in STAY Mode 1 flash until exit time expires. At the
end of exit time, all zones selected to be
automatically isolated turn off and the codepad gives
one short beep.
Arming in STAY Mode 1, Method 2
Hold down the [*] button until two beeps are heard.
The STAY indicator displays and exit time starts
counting.
Any zones programmed to be automatically isolated
in STAY Mode 1 flash until exit time expires. At the
end of exit time, the zone indicators turn off and the
codepad emits one short beep.
5.3 Arming in STAY Mode 2
STAY Mode 2 is only used when the perimeter and
unused areas of the premises must be armed to
detect an intruder from entering the premises while
you move freely within an area that is automatically
isolated. Any Master Code user can program zones
to be automatically isolated in STAY Mode 2.
Entry Guard Timer For STAY Mode 2
When arming the system in STAY Mode 2, an
optional entry timer called Entry Guard Timer For
STAY Mode 2 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and triggered into alarm condition. Entry Guard
Timer for STAY Mode 2 is the delay time used for
all zones except 24-hour zones when the system is
armed in STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode 2 is
programmed and a zone not automatically isolated
triggers, the codepad beeps twice a second until the
entry timer expires or the system disarms. If the
alarm condition is not reset by entering your user
code followed by the [#] button (for example,
[2 5 8 0 #]) before the entry timer expires, the sirens
activate into alarm. Only your installer can program
this option.