Bosch Appliances CC408 Home Security System User Manual


 
CC408 | Operators Guide | 14. Turning Outputs On/Off EN | 14
Bosch Security Systems | 5/04 | 920050O.OG.112
14. Turning Outputs On/Off
This feature only applies if your installer set up an
output that can be turned on or off by the codepad.
The output programmed by your installer can
control a pool pump, outside lighting, and so on. Up
to three separate outputs may be programmed.
How to Turn an Output On or Off
1. Enter your Master Code followed by the [5] and
[#] keys (for example, [2 5 8 0 5 #]).
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the output number (1 to 3) that you wish to
turn on or off.
3. Press the [#] key to turn the output on, or press
the [*] key to turn the output off.
Three beeps sound if the output is turned on,
and two beeps sound if the output is turned off.
Repeat Step 2 and Step 3 if you require more
than one output to be turned on or off.
4. Press the [#] key to exit this function.
Two beeps sound and the STAY and AWAY
indicators go dark.
15. Reset Latching Outputs
This feature only applies if your installer
programmed an output to latch (remain on) until you
acknowledge the event that occurred.
How To Reset Latching Outputs
Hold down the [7] key until two beeps sound. The
output resets.
16. Codepad ID/Buzzer Tone
Change
Hold down the [8] key continuously to change the
tone of the codepad buzzer. There are 50 different
tones, from 1500 Hz to 5000 Hz. If multiple
codepads are installed, each codepad can sound a
different tone.
If the system is partitioned, the keypad first displays
the area to which the keypad is assigned:
x Zone 1: Area 1 codepad
x Zone 2: Area 2 codepad
x Zone 7: master partitioned codepad
17. Te st in g
There are various functions for testing that your
system is operating correctly.
17.1 Horn Speaker Test
Press and hold the [1] key until two beeps sound.
The horn speaker sounds for 2 seconds.
17.2 Bell Test
Press and hold the [2] key until two beeps sound.
The bell output operates for 2 seconds.
17.3 Strobe Test
1. Press and hold the [3] key until three beeps
sound.
The strobe flashes.
2. Press and hold the [3] key until two beeps sound.
The strobe stops flashing.
17.4 Walk Test Mode
Use Walk Test Mode to test detection devices for
proper operation. Every time you test a zone, the
codepad sounds one long beep and the horn speaker
sounds one short beep to indicate the zone was
activated when testing.
1. Enter your four-character Master Code, followed
by the [7] and [#] keys (for example,
[2 5 8 0 7 #]).
Three beeps sound, and the STAY and AWAY
indicators flash. The codepad beeps once every
second while the system is in Walk Test Mode.
2. Activate all zones that require testing.
The codepad sounds one long beep and the horn
speaker sounds one short beep every time a zone
is faulted (unsealed) and restored.
3. When you finish testing all required zones, press
the [#] key to exit this mode.
Two beeps sound, and the STAY and AWAY
indicators turn off. The system returns to the
disarmed state.
17.5 Test Report
This feature only applies if your system reports by
telephone. Press and hold the [9] key until two beeps
sound. The system sends a Test Report without
sounding the sirens.