23. Basic Pager Reporting
This feature only applies if your system reports to a
pocket pager. Basic pager reporting requires some
interpretation of the numbers that appear on the
display. It is possible to differentiate between 1000
different systems when a number of control panels
report to the one pocket pager.
Subscriber ID Number
This is the identification number of the control panel
and can only be programmed by your installer.
Zone Status
The zone status display shows you the status of each
zone (1 to 8). Table 13 describes what each number
means when displayed on the zone status display.
Table 13: Zone Status Display Descriptions
Number
Displayed
Zone
Description
0 Zone Normal
Indicates the corresponding zone is in the
sealed state.
1 Alarm
Indicates the corresponding zone is
unsealed and in alarm condition.
2 Zone Bypassed
Indicates a system operator manually
isolated the corresponding zone. See
Section 10. Isolating Zones for
information on how to manually isolate a
zone(s) prior to arming the system.
3 Zone Trouble
Indicates a zone was left unsealed after
the end of exit time.
System Status
The system status information is divided into the four
digits identified in Table 14.
Table 14: System Status
System Status
Display
Description
First digit Indicates whether the system is armed
or disarmed:
8 = Disarmed
9 = Armed
Second digit Indicates which codepad alarm was
triggered by the operator:
0 = No Codepad Alarm
1 = Codepad Panic or Duress Alarm
2 = Codepad Fire Alarm
3 = Codepad Medical Alarm
Third digit Indicates when the AC mains supply
fails:
0 = AC Supply is normal
1 = AC Supply failed
Fourth digit Indicates when a system fault occurs
at the control panel:
0 = System Normal – There are no
faults.
1 = System Fault – There is a fault
registered by the control panel.
Figure 7 shows the transmission came from the
control panel with an ID number of 678, and zone 2
is in alarm. Figure 7 also displays zone 3 is manually
isolated and the system is armed.