Bosch Appliances CC408 Home Security System User Manual


 
CC408 | Operators Guide | 22. Partitioning EN | 17
Bosch Security Systems | 5/04 | 920050O.OG.112
22. Partitioning
You can partition or split the Solution 880 Control
Panel into two individual areas. You can operate
both areas from one Master Partitioned codepad or
from separate area addressable codepads.
22.1 Master Partitioned Codepad
Indicators
Figure 6: Master Partitioned Codepad
The indicators on a Master Partitioned codepad are
configured into four groups. The following
paragraphs describe the indicators.
22.1.1 Zone Indicators
The zone indicators (1 to 8) display the status of each
zone. These zones belong to the area whose AREA
DISPLAY indicator is lit. If a ZONE indicator is lit,
that zone is unsealed. If a ZONE indicator is not lit,
that zone is sealed.
22.1.2 Area On/Off Indicators
The group of four AREA ON/OFF DISPLAY
indicators show the status of each area. If an
indicator is lit, that area is armed. If the indicator is
not lit, that area is disarmed.
22.1.3 Area Display Indicators
A group of four AREA DISPLAY indicators
determine the area to which the displayed zones
belong.
22.1.4 Status Indicators
This group of four indicators shows the following:
AUX Indicator
The AUX indicator displays when the system is using
the telephone line to communicate to the receiving
party.
The AUX indicator flashes in conjunction with the
PARTIAL indicator to show successful entry into any
programming mode. For example, this occurs when
you are using Master Code functions.
Mains Indicator
This indicator displays the status of the AC mains
supply. The indicator lights steadily when the AC is
normal and flashes when there is an AC supply
failure.
Fault Indicator
This indicator displays the status of the system’s fault
register. If the FAULT indicator flashes when the
system detects a fault that has not yet been
acknowledged. If the indicator lights steadily, the fault
has been acknowledged.
Partial Indicator
This indicator shows whether an area is armed in
STAY Mode 1. If the PARTIAL indicator is lit, the
area is armed in STAY Mode 1. If the indicator is
not lit, no areas are armed in STAY Mode 1. When
isolating zones, the PARTIAL indicator flashes to
indicate that you are in the isolate mode. The
PARTIAL indicator also flashes in conjunction with
the AUX indicator to indicate successful entry into
any programming mode (for example, when using
Master Code functions).
22.2 Operating From A Master
Partitioned Codepad
If you have a partitioned system with a Master
Partitioned codepad installed, operating procedures
described throughout this guide are the same with
one exception. All operations are relative to the area
whose AREA DISPLAY indicator is illuminated at
the time.
Example
When the AREA DISPLAY indicator number 2 is lit,
all operations performed affect only Area 2. To
perform operations in another area, you must move
the AREA DISPLAY illuminator to the desired area.
To Move From One Area To The Next
Press the AWAY button.
The area display indicator moves to the next area.
Repeat until the desired indicator is lit.
22.3 Operating From Area Addressable
Codepads
If you have a partitioned system with Area Addressable
codepads, the operating procedures described throughout
this guide are the same. Refer to 16. Codepad ID/Buzzer
Tone Change on page 14 to determine the area to which a
particular codepad belongs.